    Problem with new Intergas boiler install. HRE 18 OV

    Hi dcuk, press the button with the thermometer symbol (second from left). The led next to the radiator symbol should illuminate. The set point temperature for the heating (and hot water cylinder if only 1 switch live has been taken back to the boiler etc.) will be displayed in degrees Celsius...
  4. J

    Water is hot from taps, but barely warm from the shower.

    Hi, does the connection into the left hand side of the shower valve remain hot all the time or does it cool down? James.
  5. J

    Keston C45 - Question Regarding Thermostat Setting

    Very common that the potentiometers go on these. One symptom is that the set point temperature flashes on the display now and again when nothing is touched. A replacement potentiometer does not require the fascia PCB to be replaced. A link between the two switch lives will provide a...
  6. J

    Water pipe - why is copper cheaper than iron?

    I'm sure iron pipe can be used for Central Heating pipework, so can be discussed in the Plumbing and Central Heating forum. :wink: James.
  7. J

    Refilling a sealed central heating system

    When system is drained shortly before refilling, close both valves on a radiator ideally a towel rail. Add inhibitor to that rad. Refill system as said start at bottom and work up. Check for leaks. Shutdown any call for heat. Open radiator valves and bleed rad. Check and adjusted system pressure...
  8. J

    Scrap etiquette

    I wonder how much I could have had knocked off t'bill if I took t'old tyres? James.
  9. J

    Scrap etiquette

    Just had a couple of tyres changed on the van today. Who keeps the old tyres? James.
  10. J

    Worcester 28i junior

    Yeah do that, then you may need to find an independant engineer anyway. Followed them on to jobs where they haven't managed to solve the problem. James
  11. J

    Replacement of Heat Exchanger Glowworm Economy Plus 60F

    Really??? I am assuming that the GC No. of your appliance is: 41 319 63? The manual can be found online with instructions of how to change the heat exchanger. If you read the manual, it states "It is the Law that any servicing must be carried out by a competent person." If you are...
  12. J

    Drayton Motorised Valves

    Twist end of springs with a pair of long nose pliers so that they hook into the hole where the lugs have snapped off. Can't recall having this problem with Honeywell valves. James.
  13. J

    Boiler losing pressure, leaking liquid & tripping circui

    +1 If someone already knows, I always think (and sometimes say), why am I asked to do the job then? James.
  14. J

    Header tank steaming

    If there is magnetite present, it usually forms a hard crust around the pipework (as well as the loose stuff that can be flushed as described above). Cut out and clean or replace the pipework then reassemble. Set pump to speed 2 and check that it isn't pumping over again. The pumping over is...
  15. J

    water pressure gauge

    If no water comes out when the system is full, how can it measure the pressure? Are you sure its not blocked? James
  16. J

    Scrap etiquette

    The link to the thread I was referring to in my previous post: http://www.diynot.com/forums/trade-talk/waste-carriers-license-free.387794/#2981379 James
  17. J

    Scrap etiquette

    With a highly desirable 'thanks' to 'posts' ratio like Norcon has (sarcasm), it looks like this thread has changed from talking about scrap to looking at carp (sp) posts from Norcon. I'm not from darn sarf and rarely work there but I understand how these rates can easily be justified, but...
  18. J

    water pressure gauge

    Original gauge may be ok. James.
  19. J

    Pump overrun

    This not sorted yet? Isolate electrics. Remove the motor head. Check that spindle moves freely by hand only. If ok, check for safe electrical isolation and replace motor. If spindle is stiff replace entire valve (my preference is Honeywell). Re-instate and test. There is no pad that sits...
  20. J

    Glowworm ultrapower six PCB fuse blows

    A half decent engineer will also have some spare fuses. James.