  1. J

    12000 BTU radiator needed?!

    I have similar age Myson Round Top panels in my house and they’re still throwing out the heat just fine. Take a look at the specs for Myson Premier HE type 22 and you will find a list of sizes and heat outputs for panels very similar to the radiators you have...
  2. J

    Nest Install Logic Combi Boiler

    Yes it’s a very straightforward replacement with the heatlink connections as you have listed.
  3. J

    Old Switchmaster control, no hot water off so..

    If you can identify those two cables ( and maybe some of the others from cylinder stat, boiler etc ) entering the wiring centre in a photo I'm sure someone will help.
  4. J

    Old Switchmaster control, no hot water off so..

    You have two Earth connections where really only one is normally required (unless the Earth is being looped through to be used elsewhere) and the Hive Receiver does not even need to be Earthed at all so as long as you can safely identify those two cables in the wiring centre one of the "Earth"...
  5. J

    Old Switchmaster control, no hot water off so..

    Is there a main wiring centre where the 3 port valve, boiler, cylinder thermostat, room thermostat etc are all wired together? It might be best to wire the Hive receiver into that location and abandon the old programmer wiring altogether, unless that cable has an unused wire to use for HW OFF...
  6. J

    What programmer is this???

    If the timer is still working it would be worthwhile trying to identify the wires with a multimeter. If you aren’t confident with that, some pictures showing how that multi core cable is wired up at the boiler end would be useful.
  7. J

    Nest install with possibly zoned system

    If the heating is zoned there should be some motorised valves in the pipework which would open when that zone required heating. Normally the thermostat for a zone would directly control the corresponding motorised valve, which would open when heat was required and also tell the boiler to fire...
  8. J

    Nest Gen 1

    Yes that’s right and the M wires in 4&5 can also be disconnected, they are supplying power to the timer motor which will no longer be required.
  9. J

    Another Hive 2 Installation

    Is the timer connected to TA1? If so you would have to remove it’s wiring to connect the Hive receiver. The timer would then have no effect on the boiler.
  10. J

    Nest: Installing the Heat Link to a

    Yes, with the boiler isolated from the mains just remove the wire link across those contacts in the boiler and connect as you say. You'll also need a Live and Neutral power feed for the Heatlink which you could take from the same location in the boiler.
  11. J

    New house vailant boiler

    Definitely setting 3. I have a similar Vaillant boiler and it doesn’t like anything less. I’m not sure it will damage the boiler at a lower setting but it needs a decent flow in order to shift the heat out into the system. It’s most likely poor flow that’s causing it to rapidly overheat and...
  12. J

    New house vailant boiler

    Google Spinal Tap. They liked to play really loud and allegedly had guitar amplifiers with volume controls that went up to 11.
  13. J

    Completely wireless heating control options?

    Liking your Intergas prayer mat Dan. I want one.
  14. J

    Madia Plate aerial connection not setup correctly

    The return is usually wired through to an aerial socket in another room (eg bedroom or kitchen) so you can send a signal from the set top box in the lounge to be viewed on another TV elsewhere in the flat. Is there another socket in the house? It may be that all of the wiring for the lounge...
  15. J

    Boiler losing pressure only when heating is off

    How high does the pressure rise when the heating is on? I know the engineer has checked the PRV but it may still be a good idea to tie a plastic bag on the PRV discharge pipe for the day to check for any water release.
  16. J

    Boiler losing pressure only when heating is off

    It's most likely it isn't really maintaining pressure all day. As the pressure naturally rises when it's hot it won't be so obvious how much water has been lost until it cools down and contracts in the evening.
  17. J

    4 core flex to 3 pin plug?

    Remarkably little acoustic energy is required to make a very considerable noise so, as Detlef says, virtually none.
  18. J

    Have I blown my boiler electronics?

    Link Live to the 240V RT connector (with the power off of course) then check briefly that the boiler will fire. If that works ok you just need to remove the link and take a single wire from Heating ON to the RT connector to get the thermostat working.
  19. J

    Have I blown my boiler electronics?

    The Danfoss is just a switch but the dual channel Hive connects mains voltages to the four output terminals and there's really no way around that.
  20. J

    Have I blown my boiler electronics?

    When you say "manual mode" do you mean setting the boiler timer to permanently ON and does the boiler then deliver heating ? If so, that is OK and is likely the only way you can allow the Hive to take control of the heating schedule.