    Optima Compact - works fine but no zone lights on walk test

    Paul , its PROG , CODE , 0 , 5 for walk test.
  2. D

    Optima Compact - works fine but no zone lights on walk test

    The original Compact 6 has fixed zone types eg zone 1 e/e , zone 2 access etc , and are not programmable.
  3. D

    Gardtec 500 intruder alarm

    As you say , the brown and blue are the 230 vAC inputs and the orange pair are the AC outputs ( to the PCB ) the reading on these should be about 18 vAC.
  4. D

    Gardtec 500 intruder alarm

    The transformer output is AC , so its not important which way round they go.Just look for the 2 terms marked AC.
  5. D

    Gardtec 500 intruder alarm

    Be very careful , you are obviously out of your depth..please get someone competent to ensure that the incoming wires are dead.The incoming mains follow normal convention , brown to the connector with a fuse...the 2 orange go to the circuit board , 2 terms marked AC or similar. But ..please get...
  6. D

    Programming an Accenta LCD keypad

    If you are talking about the Accenta G4 lcd , then yes it is simple to do.You will need the engineers code , have a read at page 34 , you just need to set up program 2 , choose your used zones (leave out the upstairs zone), select an exit mode , dependant on your layout you may have to change a...
  7. D

    Adding simple set reader to accenta mini gen 4

    Yes , I think it just acts as another RKP on the ADE system, and the relay contacts are to integrate with other kit.
  8. D

    Adding simple set reader to accenta mini gen 4

    I think the PTS connections are only used when connecting to other brands of panel , using their keyswitch zone.
  9. D

    go to ukpanels.com..they have the manuals and friendly helpers ..all free

    go to ukpanels.com..they have the manuals and friendly helpers ..all free
  10. D

    Accenta G4 alarm & garage door

    You need to find out how this relay will operate , but usually you would connect it across the garage detector NC terminals , so when you press the remote to open the door , the detector is bypassed ( or shunted) , giving you time to disarm the alarm.
  11. D

    avanti 8

    Have a look in the Alarm Sticky at the top, a magnetic contact is shown , the 2 chrome terms are the ones connected to the glass reed switch , these should go closed circuit in the presence of the magnet,
  12. D

    avanti 8

    The control panel has the following : T ..neg tamper return A..neg supply (perm) B..bell switch neg A..pos supply (perm) Strobe - for strobe. Page 4 of the AG6/8 guide tells you how to connect , just use the Optima XL4 conections.
  13. D

    No room for alarm door contacts need advice?

    Have a look at the gap between the frame and the top of the door , on most of them its bigger than you think.
  14. D

    No room for alarm door contacts need advice?

    Use a bit of blutak , and experiment fitting the 2 halves in the channels in the frame and door , its dead easy. [/img]
  15. Untitled

    Untitled

  16. Untitled

    Untitled

  17. D

    Alarm System Advice

    You don't say how many zones you require , but if less than 8 , have a look at the Cascade Avanti comes with a prox RKP as standard, but to be honest , you get more features for the extra money if you go for the Tex Premier.
  18. D

    Part setting Accenta G3 in different zones.

    You don't necessarily require an engineer.You need the engineers code and an installation manual.Have a good read through the manual , and if you feel confident , give it a go!. Have a look at ukpanels website , they have manuals , and lots of patience.
  19. D

    Honeywell House alarm

    Correct , 6 core alarm cable.
  20. D

    Temporary disconnect PIR

    You haven't told us what panel , but generally , open panel , internal alarm sounds , key in user code , alarm stops , remove the wires going into the 12+v supply terminal.Now you can remove the PIR without the fuse blowing.Make a note of where the wires go ( take a picture if poss ).