  1. D

    Frozen Keypad. Help needed

    I would guess you have blown a fuse.I would double check your repair before replacing fuse tho. Fuse = 20mm 1 amp quick blow ( there may be a spare inside the case )
  2. D

    back up battery

    You can't go wrong with a 2.1 Ah , unless its an AJ600 (1.2 Ah), have a look http://www.ukpanels.com/pics/ at some of these pix to identify it.
  3. D

    Accenta 8 Reset & Bell Box

    The system will not set with a zone fault , so check to see if any zones are lit , and find out why.You can force a quick set by pressing SET whilst the exit timer counts down. Don't forget that when setting up the ex / ent timers that 01 is 10 secs 02 is 20 secs etc.
  4. D

    Accenta 8 Reset & Bell Box

    The Texecom Odessey is a good range of bellbox, just pick your preferred shape. The Accenta will require re-programming , but the default prog is usually sufficient.
  5. D

    optima G3 panel & honeywell informa keypad

    Do you mean can an Informa dialer control an optima G3 ?, then no. The G3 keypads are less than £20 . What is the problem with your keypad?.
  6. D

    Newbie self install alarm system need help system purchase

    Hi , I would recommend quad pirs over dual techs , contacts are just to detect a door opening , whereas a shocker would detect someone kicking or banging on the door (I would think contacts would be sufficient). I would recommend mains smokes just incase the alarm fails for any reason ...
  7. D

    Alarm Trouble (Image)

    Its a Visonic Powermax ..all the info you require is in the user manual.Different detectors types use different batteries.
  8. D

    c&k securitech CO23-203 Iss 1 - how to reset the timing?

    That is an engineer programmable function , so you would need the engineer code , if you don't have this you will have to reset the panel back to default settings ( its all in the installer manual).
  9. D

    help with response alarm

    The PA8 is just a rebranded ADE Optima , try removing the mains and the back-up battery , then fire it up mains first, enter user code to silence (if it doesnt work try 0123), reconnect battery , close panel and RESET .
  10. D

    New bellbox and keypad for concept wired system

    The Odessey range all have flashing status leds , and it comes in 5 different shapes.The Texecom R8 comes with an endstation with all the wiring , battery , mains etc , and a dedicated remote keypad.Most alarm keypads are brand specific, so your ADE will not work with a Texecom. I have...
  11. D

    New bellbox and keypad for concept wired system

    Assuming all the devices are in working order , yes.The only problem you may have , is if it is an ADE Concept , then the PA and zone 1 are wired from the keypad and not from the main box, so a little rewiring required. I would recommend the Texecom Veritas R8 control panel and the Odessey...
  12. D

    Gardtec control panel

    Have you tried powering down mains and battery , wait for a few seconds , then power-up again , see if the keypad is recognised.
  13. D

    Replacement / Upgrading External Alarm Box

    It depends on your ability.Post your panel type and the new bell type , and we can provide you with what goes to what.The hard bit might be getting the old rusty screws out ..at height.
  14. D

    Texecom Premier 24 / 48 control panel questions

    There is plenty of space for the contact and magnet between most upvc frames and doors.If space is tight , remove the mag from its holder.Experiment with blue tac. [/img]
  15. D

    eurosec alarm reset

    You should press your landlady to get this sorted for you , it is her equipment.If you choose to default the panel , there is a chance the engineer code has been locked making the panel unprogrammable. The default user code is 5678.
  16. D

    Old Wickes Alarm help please

    You require a replacement back-up battery , take the old one out , take it to Screwfix and get a new one.
  17. D

    Fitting Optima G4 Compact alarm system

    Sounds like the ex/entry zone is open..this can be confirmed by what is shown on the display when the code is entered.
  18. D

    Powermax alarm

    Why have the zone set as perifery/external..surely Entry 1 would be better.
  19. D

    eurosec alarm door alert

    The alert you mention is called a CHIME , and can be dissabled by the user , but the method is different depending on whether you have a LED (red display info) or LCD (text screen).Once you know what keypad you have , search for the user guide..its freely available.
  20. D

    PIR facing sliding door or radiator?

    Sometimes its difficult to avoid pointing detectors at problem areas.Most modern detectors are very tolerant to these problems, just pick a good quality detector , a quad preferably , mount it correctly and seal any holes,and it should be fine.