  1. C

    Insulating of boiler return pipe work

    That’s what I thought
  2. C

    Insulating of boiler return pipe work

    Of course it will be hot, it’s the return to the boiler, need hot water in the summer, the boiler runs all year
  3. C

    Insulating of boiler return pipe work

    Exactly my point, contributing to heating the house in the summer, I am not trying to find fault with the installer, just thought it would be Reg or just something that’s done, now wish I hadn’t posted my question. Thanks Think we can call this resolved
  4. C

    Insulating of boiler return pipe work

    Its not part of a bypass, simply the return to the boiler, yes I will insulate it, wasn’t sure if hessian wrap wound twice would be as good as foam insulation. what surprised me is that it doesn’t even have a flow temperature indicator, just turn the knob up for hotter or down for cooler was...
  5. C

    Insulating of boiler return pipe work

    Why would I want to insulate my radiators, ??? A very strange reply, if the radiators get too hot I turn down the boiler flow temperature. Heat loss from copper is rather high, it is a very good conductor of heat. With the big drive to conserve energy, I was surprised that during the summer...
  6. C

    Insulating of boiler return pipe work

    Just had a new boiler fitted, my only concern is that the boiler inlet pipe work is not insulated, it is too hot to touch, therefore I would have thought exposed pipework of this temperature should be insulated for safety reasons. But also not insulating this pipework will result in at least a...
  7. C

    New boiler Worcester Bosch Greenstar 15Ri, comments

    think you are right there, my first experience with a boiler engineer when my valiant was installed wasn’t good, the one who came out the other day was recommended, but he said it’s the pump after checking the condensate trap and igniter, wasn’t the pump, now he says it’s a blocked HE ( so does...
  8. C

    New boiler Worcester Bosch Greenstar 15Ri, comments

    Problem is the boiler won’t run more than 15-20 minutes a day.
  9. C

    New boiler Worcester Bosch Greenstar 15Ri, comments

    That’s what I was afraid of, when you it doesn’t always work, are you referring to removing the H.E and acid washing ? Think all in all I’m better off with a new boiler, getting strange shutdowns now after 40 seconds, or the kettling, as it’s 14 years old it may be throwing good money after bad...
  10. C

    New boiler Worcester Bosch Greenstar 15Ri, comments

    Is it an expensive job to remove the H.E. and chemically clean it, also would that remove all limescale thanks
  11. C

    New boiler Worcester Bosch Greenstar 15Ri, comments

    That makes sense, as it heats up not enough water can get through the H.E. for the higher burn. Should have seen that, thanks, and yes I’ve heard this type of boiler does have narrow waterways. So could a chemical flush of the H.E. devolve the limescale, think it would need to be removed to do...
  12. C

    New boiler Worcester Bosch Greenstar 15Ri, comments

    Unlikely, everything gets so hot so quickly, Vailant say blocked H.E. But don’t see how it can run from COLD for 15-20 minutes without issue then B&C…..like to reset the fault menu, found how to do it on another forum but doesn’t seem to work
  13. C

    New boiler Worcester Bosch Greenstar 15Ri, comments

    Yes the pump was still running ok
  14. C

    New boiler Worcester Bosch Greenstar 15Ri, comments

    copied link from FB page, don’t know why it’s not working
  15. C

    New boiler Worcester Bosch Greenstar 15Ri, comments

    Thank you fingers crossed, just tried it again and still running, no idea why, wouldn’t run more than 40 seconds yesterday or all morning how can I reset the fault menu in case it’s glitched UPDATE Was running for around 15 minutes, got to 53oC then started banging and crashing again, turned it...
  16. C

    New boiler Worcester Bosch Greenstar 15Ri, comments

    Have managed to do a factory reset now, but it runs for 30-40 seconds then just stops. The fault code is weird, in that it’s showing half Zeroes then 1 flashing, don’t think that is a proper fault code, it’s an ecotec 418 plus Thanks, in the fault display menu the first one is the most recent I...