  1. nrgserv

    Storage Heater not working

    storage heater? bathroom/wet room? pardon my ignorance but is this allowed now? sorry to deviate and yes they do have resettable thermal trip as everyone else says.
  2. nrgserv

    Danfoss oil pump for C/H Boiler Burner

    not in relation to your boiler pump, but i've had one running backwards after someone re installed it. is yours?
  3. nrgserv

    maxirex D programmer instuctions req

    lol, no mention of this one! i have mailed them with a picture! cheers for the link (got loads on google earlier, probably dismissed that one cos' it were all in german!) nrg
  4. nrgserv

    maxirex D programmer instuctions req

    any one know how to program one of these, (i've never seen this type before), or better still, know where i can obtain the user instructions from? cheers in advance nrg
  5. c h controller

    c h controller

  6. nrgserv

    grundfos 25-80 impellor loose

    cheers for the replies, new pump in and working. btw, the repair held on the old pump, which was left on site just in case! next problem he has is the programmer. no instructions on how to use it, but i'll stick that in a new thread. (maxirex D programmer instuctions req) neil
  7. nrgserv

    My biggest shock yet.....Always prove dead!!

    try searching for a bad earth on your tail lights at night when its p!55!ng down and wet through. you CAN get a crack from a 12 volt dc battery. same applies to arc welding, specially when its wet. (bout 48 volt, 20 - 90A) oh, and ever played with a set of contact breakers for the coil...
  8. nrgserv

    grundfos 25-80 impellor loose

    lol, sorry forgot i'd read your post! (was more infuriated with the ps bit!) integral the impellor which is polycarbonate is a steel ring which is a push fit onto the rotor. the steel ring had come adrift from the impellor. i managed to get this out and fully epoxy back in place. sounded...
  9. nrgserv

    grundfos 25-80 impellor loose

    being customer focused also, but not a plumber, i made it work by re attaching the impellor to the rotor. after the strip and rebuild with a bit of epoxy, the customer was informed of the repair and is expecting a replacement early in the week. refitted unit at 10 pm sat night to which the...
  10. stuff

    stuff

    stuff
  11. nrgserv

    grundfos 25-80 impellor loose

    ??? yeah ok, so read the questions? cheers for the advise anyway.....
  12. nrgserv

    grundfos 25-80 impellor loose

    evening again! called out to a central heating system not warming up this aft, and to cut a story short, the pump wasnt pumping correctly. removal found the impellor spinning freely on the rotor. questions i now have are; a) anyone know where i get one before monday to get them heating back...
  13. nrgserv

    britony flexiflue pcb fault

    been there! thermocouple, r1 contacts, thermoelectric valve all good. 20mV at t.c., 14mV at t.e.v. (more than 12mV required for t.e.v.) it all actually works fine when on high fan and drawn water. it also works fine when you dig a hole in the top of r2 and over ride the contacts. just cant...
  14. nrgserv

    britony flexiflue pcb fault

    not sure on the definition of soon, but done it anyway! cheers
  15. nrgserv

    britony flexiflue pcb fault

    cheers agile, currently browsing the rest of this forum to find out how it works. (minor differences to the others i use!) neil
  16. nrgserv

    britony flexiflue pcb fault

    responses appreciated for the following problem- according to the schematic for the flexiflue in the installation manaul (WHICH APPEARS TO BE WRONG!), relay 1 holds the pilot light on through the thermocouple and theroelectric valve and relay 2 (puled in) when no pressure drop is sensed. when...