  1. S

    RSI

    i dont know, i think your likly to get big men trying to beat you into a pulp if you "wave " at them like that :lol: :lol: :lol:
  2. S

    RSI

    it herts your hand when you **** :lol: :lol: :lol: :lol:
  3. S

    Generator - Basics question.

    knew it sparkymarky, knew it was the beer :lol: and i agree RF no point debating really its about as dangerous as you are going to get plus, to get a generator that will have any decent power for back to normality running will be a beast and need to be run to the Consumer unit with...
  4. S

    Generator - Basics question.

    how will pulling the fuse or switching off the MCB break the ring :?
  5. S

    Generator - Basics question.

    all depends on loop impendence i know of a incident a few weeks ago where 3 phases were cut through in a micc cable it dident short until there were enough filings within the cable to cause a short between L2 and neutral Some numpty had put 100A BS88S at the supply head with no further...
  6. S

    FAO Agile

    dont think you can even pass commnt as im yet to find a solicitor who wasnt a bastered leech who prolonged the agony of others for extended proffit
  7. S

    A puzzler

    ive got one that beeps at a wall it beeps in my pocket whilst im walking along if wearing shorts (good line that with the ladies :lol: ) they are very sensitive, static i would imagine you will notice that if you run it past a row of MCBS on a split load board and then balck until it...
  8. S

    Are speed cameras racist?

    mcb isnt really the same thing as thats a religion and although im white if i was a muslim i could join as with christian/jewish ect faiths organisations based on colour are racist though, because as a white i couldent join either of them even if i was a police officer/lawyer because i am white
  9. S

    Are speed cameras racist?

    "Peter Herbert, an independent member of the MPA and spokesman for the Society of Black Lawyers" ERRRRRR....if it was a society of white lawyers then all teh do gooders would have a fit calling them nazis, racists ect, so why can there be a BLACK only one?? double blodey standards again...
  10. S

    Silver Polos?

    you could, but you would have to use the long armed springs that are supplied else it will only grab on the plate and not get any of the ceiling easy enough to change also your IP light cant be wider than about 5.8cm as the hole is 6.0
  11. S

    Silver Polos?

    distributed by brackenheath briticent international, part number mlv/sc for satin chrome
  12. S

    Earth Loop Problem

    dosnt always work like that actuly, although it is possible to make up work, some of the ones ive been involved in have an inspector come round to verify the works being done and needed being done in the first place, spot checks usualy if you have done the above then your off the council...
  13. S

    Earth Loop Problem

    remedials, usualy done by the company testing ;) all this is no good without ZE even more so in your case, it could be that its been failed because it has a bigger fuse than the rest, or longer cable run, or smaller CSA ect ect no good comparing it with other submains unless they are...
  14. S

    Silver Polos?

    yes they are made, they are made specificly for retrofitting those crappy old wickes and similar downlights that took screw ins(SES) i reckon got one in the van to show people on that specific item, ill find out the make tomorrow 8)
  15. S

    Earth Loop Problem

    r1+ r2 wouldent no Unless you can isolate the MI sheath at one end other wise it will likly take the alternate route that the EFLI test took you should really be able to calculate what your looking for but we need to hear the ZE!!!!! and a rough guess at cable length would do...
  16. S

    CSA of CPC of 6mm2 cable?

    8) but who the hell uses an odd size and pays more than they would for about 2 cable sizes above :lol:
  17. S

    CSA of CPC of 6mm2 cable?

    although it is also avaliable in 6/2.5 , 6/4.0 , 6/6.0 i remember a discussion long ago about that and i checked myself with my wholesalers and it does indeed come with 6/4 and i would imagine 6/6
  18. S

    Earth Loop Problem

    RF is spot on there i was thinking more along the lines of a joint rather than a break as you say magnesium oxide sucks more than a back street whore so you would notice prehaps a numpty has used a plastic joint box and not linked...
  19. S

    Earth Loop Problem

    well if its old and in such a state that it would trip an RCD then that a fault, isnt it and so the instalation is unsatisfactory........ RCD only does its job and if the wiring is in such a state..... but agree, RCDs in schools are a bad idea if possible to avoid due to teachers not...
  20. S

    Earth Loop Problem

    should you really be doing this in a school if you have to ask on a diy forum? :? anyway, The earth of a 25mm MI cable will be large even if its just the sheath, are you sure theres no break in the sheath of the cable at some point? is there an extra earth core? RCD isnt ideal but can...