    Gas pipe sizing

    ................whos doin the pipe sizing right and ensuring the safety of the customer. :wink:
  2. B

    Gas pipe sizing

    I work it out by like this .......... pressure loss is calculated (assuming a 1mb permissable drop) by dividing 1 (mb) by the number of sections to the appliance, in this case lets assume 2, that means that 1divided by 2= .5 This figure is then X by the length of that section (say 20m) this...
  3. B

    bending 40mm pushfit plastic pipe

    no -officially, yes - if you heat it up! I wouldnt though (maybe for a slight curve) use proper fittings instead...proper job!
  4. B

    Gas pipe sizing

    Kev: wrote where you talking to me :?
  5. B

    Gas pipe sizing

    Or put simply ...dont forget the permissable drop allowed from the meter to the inlet of a gas appliance AND the equiv length due to fitting\bend restrictions. 2 different calculations mate.
  6. B

    Flushing a radiator yourself - how?

    attach a hosepipe by way of fittings (not holding it on) and block the other end of radiator (i use my foot!) this will build up the pressure..then hit the radiator with a rubber mallet then release foot, repeat this a couple of times till the water runs clear, also flip rad for the ultimate...
  7. B

    Gas pipe sizing

    also.........dont forget the allowed installation pressure drop that must be divided and converted to an equivalent length!
  8. B

    Gas pipe sizing

    everyone knows something but nobody knows everything, i think, I'm confused know or is that now :oops: ps - edited my last post :wink:
  9. B

    Gas pipe sizing

    nobody knows everything but being able to understand the regulations and interpret the terminolgy requires a specfic knowledge that some people may have and some people may not have. A Judge does not know every law off the top of their head but he can referance AND UNDERSTAND the relevance and...
  10. B

    Gas pipe sizing

    .........so going by the unwritten rule i will abstain from giving any advice (as it could result in a dangerous situ more than likely because im still a newbie and not because your not an RGI but probably both :D) ...no hard feelings :wink:
  11. B

    Gas pipe sizing

    are you an RGI?
  12. B

    Speedfit installation advice

    ammended............(no not your fly buy night, it'll be ok with some MDF, paint and plastic pipe type)
  13. B

    total newbie question

    identify the 22mm (maybe bigger) pipe from bottom of big cold tank that enters the bottom of the cylinder, this is the hot water cylinder feed and there should be a valve on it turn this and it will isolate your hot water to the taps........hopefully! and you are looking for something like...
  14. B

    central heating

    i think he is :wink:
  15. B

    Worcester on the outside but not on the inside?

    So it was a Thorn boiler but a Worcester Bosch designed unit? Cant remember why he wanted tech help - the system was powerflushed and the heating wasnt working - mentioned an inaccessible diverter valve blah blah blah....... :D .
  16. B

    Worcester on the outside but not on the inside?

    Engineer in work the other day went to sort an old and battered WB hiflow\heatslave thing out and had to ring WB tech help, he gave them the GC number and they responded that it wasnt a WB GC number, the engineer then told them it is a WB theres a great big Worcester badge on the front cover...
  17. B

    what power flushing machine should i buy?

    make sure its a 'double dumper' as the single dump Kamco i used the other day would not flush the rads proper due to one way TRVS. had to do a manual drain!
  18. B

    Hot Water Tank

    If it looks like this http://www.h-i-e.co.uk/acatalog/zone.jpg then id the one that is positioned on the pipe before it enters the hot water cylinder and turn hot water only on. does the boiler stay alight? does the pipe that runs between the valve and cylinder get hot (alot hotter...
  19. B

    Hot Water Tank

    do you have any 2 port or a 3 port valve\s? Does your heating work alright?
  20. B

    hot water storage cylinder leaking intermittently ??????????

    ......also glue the overflow pipe connections together so they dont leak again :wink: (if they are in fact the cause of the leak)