  1. Andygasman2010

    Ravenheat RSF 620/20 No hot water

    You've done very well to have a perfect Ravenheat for 10 years! That's got to be a record. You may well have a split hot water diaphragm and the diverter valve may also be passing to the rads. You can replaced the whole valve...
  2. Andygasman2010

    Worcester Bosch 24CDi and pinouts for a WIRELESS Roomstat

    Take the link out and wire it to terminals 1 and 3 of the receiver back plate (doesn't mater which way around you put them) Take the permanent live from ST12, it doesn't matter whether you take the neutral from ST12 or ST8. 4 wires all together, no need to earth the back plate.
  3. Andygasman2010

    Central heating just doesn't work properly anymore.

    What kind of system do you have? Y-plan, S-plan? open vented or sealed system? You may have a blockage around the feed/vent which will give you this problem, plus it will be pumping-over and pulling in aerated water which is why your rad needs bleeding all the time. If all this is jargon...
  4. Andygasman2010

    CH Sytem vent pipe diameter

    You're thinking too much!
  5. Andygasman2010

    Wireless Replacement for Randal 103

    Yea something doesn't seem quite right... OP, can you get hot water on it's own if you turn the thermostat right down?
  6. Andygasman2010

    Wireless Replacement for Randal 103

    Please tell me I'm NOT going insane :D :shock:
  7. Andygasman2010

    Wireless Replacement for Randal 103

    The second sentence on this thread.
  8. Andygasman2010

    CH Sytem vent pipe diameter

    I know the benefits of non-return valves but they shouldn't be needed anywhere on a fully pumped system. Being 28mm pipework you will have a very good flow rate and probably get away with pump speed on 1. How many radiators do you have? What's the heat input of the boiler? (sorry if this...
  9. Andygasman2010

    CH Sytem vent pipe diameter

    There shouldn't be any non-return valves anywhere, don't do that. Try turning the pump speed down and possibly piping it like the diagram I posted.
  10. Andygasman2010

    CH Sytem vent pipe diameter

    This all depends on how much effort/money you want to throw at the problem. The ideal solution would be to seal the system completely, what boiler do you have?
  11. Andygasman2010

    Wireless Replacement for Randal 103

    There's already a thermostat so it can be done how I describe above, can't it? I mean with a hard wired programmable stat, not a wireless one.
  12. Andygasman2010

    Wireless Replacement for Randal 103

    WTF :shock: I must be missing something here... The 103 IS suitable! It turns on the heating and water at the same time, it doesn't control the pump, that'll be the job of the 2 or 3 port valve/s or the boiler (not sure if it has a pump overrun) The 937 is NOT suitable as a direct...
  13. Andygasman2010

    Low Pressure in Shower Y Plan Condensing

    What shower have you got? You might need to fit a shower pump.
  14. Andygasman2010

    Ideal Icos m30 80 showing demand?

    Something is wrong here! How many temperature control knobs are on your boiler? Do you have on for the heating and one for the hot water?
  15. Andygasman2010

    CH Sytem vent pipe diameter

    Try combining it like this
  16. Untitled

    Untitled

  17. Andygasman2010

    worcester 240 with blank display

    Yea, I put a link to it above.
  18. Andygasman2010

    worcester 240 with blank display

    You'll fine the electrics a piece of P*** then mate. That integral timer will have 4 wires to it, L-N and the switch. Doubt it'll be earthed. You can either get a time switch (any single channel timer will do) and wire it to those wires, or... Make the L-N safe and link the switch. Then...
  19. Andygasman2010

    worcester 240 with blank display

    The integral clock is now broke. But I guess you already knew that! It's highly unlikely that it can be repaired so It'll need to be replaced. You don't have to get a like-for-like clock, an external timer or programmable room stat will do. The knackered clock can be bypassed for the time...
  20. Andygasman2010

    Ideal ConcordeWCF-255A - not firing up

    He's saying there is power to the gas valve which would only come from the Y or S plan valves. It could be gravity though, possibly a C plan.