Search results

  1. W

    Glow worm 30CXi pressure problem

    I have replaced the pressure sensor, got a bargain for £15.90 delivered on ebay. It has immediately fixed the pressure indicator display. First of all the pressure was set to 1.4 and the CH put on. As the water got hot the pressure rose to 1.9, and tonight it went up to 2.8 There was no...
  2. W

    Cold Radiators

    To give this post some context.......I am an amateur, DIY, I just fixed my boiler.....I'm still learning...aren't we all? Your numbered valve is a 'TRV' on the opposite side of the radiator is another valve called a 'lockshield'. Shut all other radiators in the house off using the lockshield...
  3. W

    Boiler pressure loss after service

    Thought a PRV only leaks through the copper overflow?
  4. W

    Glow worm 30CXi pressure problem

    I do have a pink one, Yeah I just read on another thread here about opening the PRV, nevermind, it might have been leaking anyway, still don't know where the leak is coming from, but the boiler is out of use for another day, I will get a draining pipe for tomorrow and check out the sensor and...
  5. W

    Boiler pressure loss after service

    what fault does water collected in a bag over condensate pipe when boiler switched off indicate?
  6. W

    Glow worm 30CXi pressure problem

    I have been bleeding the upstairs rads too much, first of all with the bleed valve open nothing came out until the CH was switched on, then some air and water came out. But it had to be done again the next day. someone else said there is a leak (possibly pressure relief valve), well there...
  7. W

    Brick arch and modern lintel need repair

    Hi, The questions are, How do you repair a brick arch which is slipping, and how much do you think a builder would cost? Do you think there is a problem with the modern lintel? What would you do to repair it or increase it's strength? Is there a Victorian lintel design which would...
  8. W

    Brick arch and modern lintel need repair

    I vaguely remember that this forum (diynot.com) is linked to usenet (newsgroups) is this true? Is this a standalone internet forum or do posts/replies appear in/come from usenet? Onto my question, I'm looking at a house to buy, and it has UPVC french doors onto a patio above the doors...
  9. W

    gable end

    The reason was that it was heavily cracked, not blown, only a small amount was blown.
  10. W

    gable end

    Good question, about 10 mm, over all, in some places chunks of 20 - 25 mm, also I just remembered their hammer cracked some of the bricks clean through. There is no cavity just a wall two bricks thick (the length of one brick). Nothing holds it up except the rendering on both sides internal...
  11. W

    gable end

    I live in an end terrace, my gable end is constructed just 2 bricks thick about 8 inches. recently we had the exterior rendering re done, they used a kango hammer chisel type thing to get the old stuff off, they took with it a good portion of the outer brick face too. There is no movement...