    Yet another Powermax 155x problem

    bottom right of unit??..... pipes are usually marked
  2. K

    potterton kingfisher rs50 boiler

    Sorry, thinking of newer model......... sounds like the thermostat when its shutting off on temperature
  3. K

    Halstead Ace

    venturis partially blocked :wink:
  4. K

    potterton kingfisher rs50 boiler

    Last one I saw did that the gas valve was at fault, can wreck the pcb too if short gets violent
  5. K

    Halstead Finest Gold Boiler Lockout Problem?Anyone Know Why?

    Venturis are a pain on all Halsteads of the era, either partially obstructed with corrosion or plastic ones melted down. Either way when it goes to high flame the air switch drops out and locks out.
  6. K

    Yet another Powermax 155x problem

    Check the circulating pump for the store........ sounds like its failed so burner only heats the store a bit until it cuts out on temp
  7. K

    Keston C25 - nobody knows what's wrong with it!

    This sounds awful like a temperature related issue be it circulation, pump issues or possibly faulty thermisters, boiler fires up then runs until hot enough then waits until the overheat stat has cooled then round the houses again. Havent checked the fault lights for the C25 in the manual so...
  8. K

    Need help adjusting the system pressure gauge on my boiler

    Where do we start??.....The key is inserted into the hole as far as it will go and twisted half a turn so it will not pull out , please try to pull it out , if it is correctly located it cannot be pulled out. There should be a little round valve handle next to the key which when turned lets the...
  9. K

    Miele HEPA 5280

    Miele 5280 HEPA hoover, hoover packed up, checked and power supply up to motor. Black and brown wires have 240v on them so Im suspecting the motor . If this is the case can any one confirm my suspicions and is there any way of testing the motor ?...... and is the part expensive?? I am a boiler...
  10. K

    Baxi 105HE - Intermittant problem, no HW or heating

    Classic fault nothing but pump.......... PCB sorts it, done a few of these for some reason of late, both Main and Baxi versions
  11. K

    baxi bolier

    Depends on what boiler......... most plate heat exchangers are in the lower section at the back and can be obstructed with hard water conditions or sludge . But........ is the hot water working okay???..... If so why replace the PHE ??..... Power flushes can be done by any decent firm and...
  12. K

    baxi bahama power flush

    I know where you are coming from, we look after all Homeserve stuff up here in SE Scotland and we are asked to to notify if systems are totally gunged up and rightly so in most cases . I tend to only report the real basket cases as the soft water up here means it isnt too aggressive on systems...
  13. K

    Central Heating and Boiler Will Not Turn Off

    Motorised valve switch sticking/ stuck ............
  14. K

    worcester heatslave 20/25

    Did he check and clean or change the tank filter??....... had a few of late where its just choked and starving the burner of oil. Sit for a few minutes the oil seeps through so you get a wee bit longer or the flame cuts in and out as the pressure fluctuates from the pump and sometimes locks...
  15. Untitled

    Untitled

  16. boiler bits

    boiler bits

  17. K

    No hot water!!!!

    Oh the joys of discussion using the powers of second sight......... Now we have identified the part would love to know if it gets fixed :lol: :D A wee round of applause to all the lads on here that regularly offer brilliant diagnosis on the basis of no information other than a vague...
  18. K

    Glowworm Micron 40ff Pcb problem?

    Lots of problems with the thermisters on these too....... Make sure correct one fitted for 40FF........
  19. K

    No hot water!!!!

    Mixing valve faulty......... reading the crystal ball here but it sounds like a thermal store with one pump for the boiler to heat the cylinder and one for heating, usually has a mixing valve to control hot water temp...... could be goosed???/
  20. K

    Boiler Problem - Ideal Classic FF340

    Pilot injector partially blocked, soon as main flame lights the pilot pressure drops off and it intermittently loses the signal to the pcb and gas valve. Only real cure is to clean the pilot injector :D