    Worcestor Highflow 400 RSF

    Diverters are a common problem with these boilers. Assuming the store temperature has been satisfied , check the flow switch is working so boiler knows if taps are opened, check power supply to diverter goes on/off with stat ( plug on pcb)....... Boiler may be running heating on dhw stat if...
  2. K

    Fit new Potterton Suprima PCB - doesn't work - please help!

    I have literally changed dozens of these PCBs and the red light will light up at the slightest excuse. Does the boiler have a flow switch?.... Is the pump powered off the boiler ? It isnt heating a Gledhill unit or thermal store is it?? Usually its caused by a basic wiring fault , thermisters...
  3. K

    ocean alpha 240p

    Fraid so...... , they dont sell individual bits of the diverter apart from diaphragms to the best of my knowledge although Vokera put a selection of spindle seals in the Excell and Maxim overhaul packs which sometimes suit other boilers diverters.
  4. K

    wood burner/oil boiler central heating

    Yes it is but usually if as some of our customers wish due to the price of fuels these days they want to burn wood as they have a forest at their back door and use the oil or gas as a standby it involves a neutraliser and a lot of pipework they shy away and have one or the other. As a result we...
  5. K

    creating a vacuum - bunging feed and expanison tank

    Yes you can bung the tank at the vent and feed and it will effectively air lock the system but its not perfect usually. In my experience it slows draining water to a trickle which makes it easy to change a trv or such providing you can catch the trickle with a basin or towel from the open ends...
  6. K

    Any clever people out there?

    Ive unblocked some strange things using a roll of solder, its so flexible it goes round all sorts of corners if you form a rounded end loop. Mostly choked condense pipework but its worth a try!! And if it is an object it may get past and hook it back the way......... nothing ventured. Good...
  7. K

    28 si mk2 worcester

    Pcb,s are a disaster in these, remove fan plug and try , if 240v on board ,check fan, if no 240V present 99% chance its the board thats goosed. 9 out of 10 faults Ive repaired are the boards on these .
  8. K

    microgenus A77 error code

    Jeez....... school playground for a simple fault.... A77 nearly always because the sensors are all slimy or mouldy from the crap in the top chamber, remove fan and clean inside chamber and sensors with blue roll or whatever and reassemble, always worked for me!!
  9. K

    Powermax 140

    How old is it ?? Direct swop integral or external programmer?? If its the reasonably newish model with integral programmer, isolate power and it can be changed by removing casing top and front , removing fascia screws and bringing fascia forward, unplugging clock and juggling it out by...
  10. K

    ideal classic ff240 central heating boiler

    You replaced the bearings??........ unusual in this day and age, the whole fan is usually replaced. If the fan has been reassembled correctly and operating normally then the air pressure switch is next in the sequence, is it being made??.......... Is this a good time to suggest or enquire if...
  11. K

    Alpha CB28 Problems

    These diverters have a strong spring in the diaphragm section so dont lose the bits !! and be very careful you put it together in the way it came apart. Also the 0 rings to the cold main connection are very suspect and leak more often than not so new ones and silicone grease to put the rings...
  12. K

    Worcester 240 combi RSF

    These Worcester fans have a speed control resistor?( I think thats what it is) on the fan itself, on heating the fan starts on high drops to low and then fires if air pressure switch has been satisfied on high speed and drops out on low . If this resistor is faulty the fan stops instead of...
  13. K

    Central Heating Zone (2 port) valve

    If I remember correctly, the white is the same as the orange on any other ACL or Drayton 2 port valve.
  14. K

    Vaillant Ecotec plus 428 SFh CODE??

    Thankyou fellas , problem sorted after deciphering a misprint in the manual!! It is indeed Service for heating i.e test program for gas analysis, the LPG conversion is very simple but when you get codes that are not listed you naturally think what the h*** have I touched?? Boiler running...
  15. K

    Vaillant Ecotec plus 428 SFh CODE??

    Just installed a Ecotec Plus 428 ,did the adjustment for LPG and when trying to get it tested on the gas analyser pressed plus and minus but all I get is the SFh flashing, No P1 for high fire so I can test it although it seems to be running just fine on low and high fire as I tested as it ramped...
  16. K

    dodgy pcb`s

    Couldnt agree more, all that range thro Si, Si2 , junior all use similar range of pcbs, have witnessed the flame lighting up with no fan running a few times. Its the relays sticking as APS is relaxed on ignition phase and only makes when fan speeds up for high flame, in short, ignition can...
  17. K

    Vaillant ecotec plus 418 Boiler wiring problem

    Just checked and 4 is definitely the right terminal for a 240v feed from external controls with link removed. remove the switched live wiring from 4 and switch boiler power on, test terminal 4 for 240v , it should have nothing if tested with a neutral or earth on the other meter probe. If it...
  18. K

    Vaillant ecotec plus 418 Boiler wiring problem

    Have you removed the link between 3 and 4 ?? The link must be removed before any external controls are wired into the boiler. These boilers are either volt free through a volt free switched clock or room stat using both 3 and 4 as the switch circuit or by wiring the switched live output from...
  19. K

    Worcester/Bosch 28 Si II - front water press guage dropping

    Sounds like a leak, tho expansion vessel worth a check if pressure rises to 3 bar and over whilst operating, water will be dribbling out of the safety to outside if the vessel is faulty. If pressure reasonably steady whilst operating then check for leaks! :D Red pointer dont mean much , it can...
  20. K

    Ideal Isar M30100 - heating on but not firing

    Had lots of these Ideal diverter actuators jamming , i.e motor spinning in actuator but not moving spindle so boiler thinks its on hot water , tries to keep the preheat temp up but ends up heating the whole heating up to 80 degrees!!.......... Isar, Icos ,Istor etc etc.......crap crap crap
Back