Search results

  1. K

    Baxi 100 keep having to reset

    If its the Baxi 100 HE , the old favourites are combustion door seals blown away or leaking upsetting the air side thermistor on overheat which cuts it or or the condense trap full of crap which shorts out the ignition circuit when it gets a wee bit too much water on top of the s*** and cant...
  2. K

    Ferroli Modena 80e hot water sticking on

    just for infos sake........ flow switch / turbine was at fault.... sorted , for those who like answers
  3. K

    Ferroli Modena 80e hot water sticking on

    Wee addition , Ferroli Technical guys had never heard of it and suggested the thermistors changed as we all know these are a weak point. Original fault was boiler occasionally switching itself on and unexplained lockouts........ another engineer changed the main board before I got there...
  4. K

    Ferroli Modena 80e hot water sticking on

    Any of you guys come across this?? Turn hot tap on boiler fires and runs normally for hot water, turn tap off relay rattles like mad on new main PCB and keeps hot water light on , stops for a mo then relights kettling the boiler. Tried unhooking dhw flow switch, this doesnt cancel light ...
  5. K

    Alpha 240 P

    Certainly do, want an e mailed copy??
  6. K

    Potterton Suprima 30L

    Replaced loads of PCBs on this range and the boys are right, it sure sounds like a new PCB, random crap like that is nearly always that big box of replacement chassis and pcb , wires everything!!
  7. K

    Vokera Excel very noisy

    Ive come across this before and its usually down to the bobbin ( the plastic bit in the service kit) getting choked or not sealing front or back depending if on heating or hot water i.e the O ring on the back of the bobbin coming off or not sealing properly . Take it out and check its assembly...
  8. K

    Potterton Prima 80F Fan Cycling on and off

    Hard to say but in order to progress with the ignition sequence the air pressure switch must be made and stay made so that the boiler knows the fan is running if not it locks out. It could be that it just isnt lighting because of poor ignition spark and the boiler is retrying until by chance a...
  9. K

    Thorn M Gas-Fired Boiler - Probably 20+ years old now shutti

    Sounds like the thermocouple is cooling when the main flame fires, probably caused by a poor pilot flame i.e crap in the pilot jet . Get it serviced, mention your problem, any good CORGI engineer should sort it.
  10. K

    gloworm boiler

    Cant agree with ChrisR enough, dont meddle with gas stuff unless you are qualified, accidents with gas usually mean fire , explosions etc.and insurance companies just love you coz they dont have to pay out to rebuild your house.
  11. K

    gloworm boiler

    Ok short reply........... CORGI Engineer to clean pilot jet, replace thermocouple if we are all right boiler should work......... :shock:
  12. K

    gloworm boiler

    The thermocouple is a safety device so that your boiler if it has a pilot flame and it goes out for whatever reason gas will not continue to flow unlit into the combustion chamber , it should if all is normal shut down the main gas valve when there is no flame present . They are normally...
  13. K

    How to fill a very large bath

    Always wanted to learn how to sail somewhere warm, Im assuming the car and trailer will fit in the bathroom too ??
  14. K

    Lockout light on Boulte Camray 3 oil fired boiler

    Sounds like the ignition isnt firing , the click is probably the oil solenoid opening allowing oil to the jet but then if you allowed the filter to be clogged by crap from the bottom of the tank then it may well be the oil not getting to the jet and the ignition is firing but no oil to light...
  15. K

    How much to fit new boiler?

    I think we are exposing a nerve with some of our buddies South of the Border here and Im finding it very amusing as a Scot, perhaps we are less forgiving in Scotland. All I think I am saying is that this job in my own home working town is a bit pricey for what the original messager stated but...
  16. K

    How much to fit new boiler?

    Sorry to sound cynical to my fellow professionals......... £1000 profit in 1 days work , what van is it???..... gold plated, do this job 5 times a week and its £5000 a week without overtime , a cool quarter million plus a year in profit alone....... The Queen would insure you herself! Get real...
  17. K

    Potterton Puma 80

    Its probably the pilot coming off the thermocouple when main flame fires up, usually due to a poor or partially blocked pilot , either way its a CORGI engineers job to repair. Thermocouple cools as pilot comes off it and shuts down the gas valve. Good luck....
  18. K

    Bath tap direction of turn to operate

    Thats probably Italian or Spanish manufacturers for you, strange ideas occasionally.......nowt wrong with it if it works.
  19. K

    Central Heating switching off before temperature reached

    Sounds like a pump problem here....... boiler is reaching temperature and cutting out , cooling naturally over 20 mins and cutting back in but no heat is getting circulated to the radiators,hence only running for a minute after initial heat up, check the pump is running. Hot water is probably...
  20. K

    combi boiler

    Send for Scotty..........Its the dilithium crystals they're gonna blow captain!! Nothing like a lack of info .........
Back