  1. F

    Ariston Eurocombi A23MFFI Hot Water Problem

    the fault could be a partially bloked domestic hot water heat exchanger,good luck
  2. F

    Ariston Micro Genus HE32 MFFI pressure problem

    sorry air in vessel is .7 bar air. 1to1.5 bar water pressure,vessel holds 7 litres of water sorry for previous wrong pressure ,good luck
  3. F

    BG Interview help please

    if you can talk like you know everything and dont want any mates then this is the job for you ,if you want a good job look elsewhere ,good luck,
  4. F

    Commissioning a New CH Pump ( e.g. Grundfos )

    just loosen of the big screw on the pump and when a small drip of water comes out tigten it up job done, good luck.
  5. F

    Pump Continually Running

    check the microswitch in the zone valve sometimes they stick,good luck
  6. F

    Baxi Bemuda 552 back boiler

    this boiler is open flued
  7. F

    Baxi Solo 15 HE repeated ignition attempts

    have you had the gas meter checked its possible you have a faulty meter governor if you have a gas cooker is it burning ok if so the governor could be ok if not call the national gas emergency service to check this is a free check ,good luck
  8. F

    Ariston micro genus combi boiler

    this is a faulty recouperator and small pcb the one you have on the boiler will have a mauve wire on the recouperator this has been updated and moved to a new postion and the new one is a black wire the small pcb is changed at the same time.good luck
  9. F

    Potterton 50 lockout

    sometimes when the pcb faults it does effect the gas valve but most of the ones i changed the gas valve has been ok,you will however need to change the thermista at the same time as changing the pcb,good luck.
  10. F

    Ariston microcombi 23/27mffi timer

    yep the timer is faulty make sure you get the correct one they are not to bad to fit but they do make 2 that look the same 1 is 240 volt and 1 is 3 volt so watch out for that good luck
  11. F

    Replacing a Potterton EP 2001

    depending on why you would like to put your timer on more than twice a day here is an easy cheap idea for you to think about,get a mechanicle timer the type you plug into a socket,plug it in then plug in your boiler supply plug into it and put your ep2001 on constant,sorted.
  12. F

    Microgenus noises

    coming on with a thump if gas pressure is correct 11 mb high 3 low then a flame gaurd is fitted to the front of the burner to assist cross lighting on start up,goaning noise are there any deadlegs on the pipework this could cause this.good luck
  13. F

    Potterton - Suprima 80 problem

    check out BBC WATCHDOG potterton suprima you will get a surprise pott now do a fixed fee repair
  14. F

    Boiler - Hot water goes luke warm

    if the system was not flushed when the boiler was installed then muck in the domestic hot water heat exchanger could be the problem.
  15. F

    Baxi Bermuda 552 Boiler Problem

    have t agree with bengas get it checked by a corgi engineer dont take any chances.
  16. F

    Halstead CH wont turn off

    if this is a standard boiler not a combi then the problem is a faulty syncron motor in the zone valve,good luck
  17. F

    Unvented Systen losing Pressure

    to check the heat exchanger is leaking into the condense leave boiler off and go to the end of the condense pipe if there is water coming out the heat exchanger is leaking ,goodluck
  18. F

    Help with boiler fault on dhw

    sound to me that the domestic hot water heat exchanger is partially blocked ,it will require exchanging if it is.and possibly the sytem may require a flush if it is blocked goodluck
  19. F

    MicroGENUS HE - No hot water/No heat coming through central

    well here we go E34 is a faulty air pressure switch unfortunately even the new ones they supply dont work very well.AO3 is either a stuck pump there is a fault with them,but they also stick if the system has not been flushed properly,or the overheat stat on the pipe on the left of the heat...
  20. F

    microgenus 23 hot water fault

    you can get this at most agents about 50 quid its held in place by 2 allen key headed bolts and you will need an allen key with a ball end to get the one out from behind the pump its a bit fiddly and water runs down the wall as you remove it if in doubt get a qualified gasman to ex it ,good luck