  1. B

    VCW advice please

    is it a vaillant, i'm thinking it is and i,ve been to a lot of the 242's that do that and there all set at about 8mb (or is that the 142's i cant remember) when on the badge it says max 5.3mb. its just one screw, you will need to snip a loop of wire to get to it i(if no-one has done it before)...
  2. B

    motorized valves

    ok chrisr what 3-port diverter does not spring back just out of interest
  3. B

    TESTING FOR INHIBITOR

    if you are that bothered if there is inhibitor in your system just put some more in, it wont cause any harm and will cost you less than £20
  4. B

    Brittony Combi 80 Keeps Cutting out

    what i would do is take the front off, and on the left hand side you will see a plastic thing with a load of wires connected to it, thats the diverter and they are prone to sticking. whack it with a screwdriver a good few hard hard times until your dhw pipe starts runnin hot
  5. B

    motorized valves

    hw should be prority and should spring back there when your heating is off so if your ch is working fine then the valve is maybe just stuck and possibly be freed. either that or the clock maybe faulty or the cyl stat maybe faulty
  6. B

    UNSAFE BOILER....!!!!

    an at risk situation only requires the engineer to turn off the appliance not isolate it from the gas. he should have told your mother in law that the appliance if used could be dangerous but it is up to her if she wanted to use it. it was obviously passing flue flow and spillage tests.
  7. B

    Fan Change on Boiler

    i think the replacement fans for ideal classics, you need to add some wire yourself as theyve moved a connection on the coil to the other side and the old wire doesnt reach.. am i right??
  8. B

    Worcester 24i No pilot flame............HELP!!!

    it will be fitted on your wall in your hall/living room if you have one.
  9. B

    Potterton Profile 80e Help Needed!

    well i doubt u will need both, if there isnt any power to the gas valve while its sparking then u probably need a new pcb, if there is power to the gas valve when it its sparking then u may need a new gas valve but it could be a blocked pilot injector or even simplar - a tripped quantum...
  10. B

    Baxi bahama not heating

    did u try swapping the thermistors connerctions over
  11. B

    Baxi bahama not heating

    oh no sorry i know how these work and they fire up before it detects a flow on the ch but if it hasnt detected a flow in 10secs it shuts off so even if ya ch flowswitch or ya pump was had it it would still fire up
  12. B

    Baxi bahama not heating

    so ya ch flow switch is knackered?
  13. B

    boiler noise

    how long has it been on before it starts banging? if its been on a while maybe the thermostat isnt cutting it off causing it to overheat
  14. B

    Baxi bahama not heating

    i cant picture the inside of the boiler but if its anything like the genesis try swapping the connections over between the hw and ch thermistors (thats if it the same setup which if it aint ignore this!)
  15. B

    central heating system problem with filling

    have you put your heating on and tried it, have you tried getting air out of the vent in your airing cupboard? other than that it could be a blockage in your cold feed
  16. B

    Fitting new 5111603 PCB to suprima 50

    thereis a common fault with suprima boards that happens to them.you get this, when it cuts down on the boiler stat or room stat it doesnt come back on and you have to reset it all the time.
  17. B

    280rsf

    if it isnt working it wont motor over. if it has been changed before the screw for the head will be facing you so engineers can change the synchron without taking the whole thing out first, otherwise the screw is facing up right under the expansion vessel making it impossible to get at. it needs...
  18. B

    Danfoss TP5 Installation

    it wont be a neutral wire, connect either one to common and it should tell you on the back where to connect the other one, if you turn the stat up and the boiler goes off and vice versa youve got it in the wrong place, just change it
  19. B

    More Hot Water Problems

    check a gate valve on the return pipe from your cylinder coil isnt partially shut off