  1. M

    help with ecoTEC valliant 831 and heating

    From all of those 3 drains on the ground floor and attached is the trv but does not say what it is I think trv4 ? Or newer model they were put in 2019
  2. M

    help with ecoTEC valliant 831 and heating

    This is how I drain, I have 3 of those drains on the bottom floor.
  3. M

    help with ecoTEC valliant 831 and heating

    I put boiler to no heat, and connect hose to the drain pipe on the lowest point and open air vents and let the water go down. For the filet I isolate the 2 taps on the filter open the bottom screw yet the water drain and then I open the bottom valve (the one on the pic) and let the return...
  4. M

    help with ecoTEC valliant 831 and heating

    I have a bit of dirt from magnetic filter at the bottom and made picture as well if the water from the drain
  5. M

    help with ecoTEC valliant 831 and heating

    So I have drain water from the magnetic filter and dirty water came out so I’m draining the system again and will do it few times this is the water is coming out from the hose not sure if it’s dirt or it’s colour from inhibitor I have uploaded the video to one drive as I can’t post videos here...
  6. M

    help with ecoTEC valliant 831 and heating

    As I said above I have read up many times on the balancing and I have tried to do it again yesterday, but when I open all the valves and lock shields not all radiators will get warm so I can’t even finish the first step of marking them in which order they heat up. The boiler will heat to set...
  7. M

    help with ecoTEC valliant 831 and heating

    I might have one of those valve next to cylinder, the difference between d40 and d41 is about 4 degrees, the return pipe feels much warmer then when running radiators. The boiler goes above the flow temp as well and cut off but it could be that the cylinder is already hot or maybe the same...
  8. M

    help with ecoTEC valliant 831 and heating

    ok when I run just cylinder the return pipe feels much warmer at the cylinder and under the boiler, probably not as hot as the d41 shows but its very warm I can hold it maybe 15-20 sec and gets very warm in the hands, where the flow I can hold it for maybe 2 sec before its burning my hand where...
  9. M

    help with ecoTEC valliant 831 and heating

    when only cylinder runs the return pipe does not feel hot under the boiler, I will check the return around the cylinder once it heat up again but if it's not hot under the boiler it wont be hot there either for the automatic vents do you mean those ...
  10. M

    help with ecoTEC valliant 831 and heating

    yes it is combi boiler ground sink is supplied directly thorough boiler and the top bathroom showers are using hot water tank and pumps if I increase the stat on the tank and put both CH and hot water tank the difference between d40 and d41 is still 5 degrees and the flow temp still goes above...
  11. M

    help with ecoTEC valliant 831 and heating

    thanks so far for the input, I have recorded 2 vids to show how the temp is rising I have put links to one drive as they are too big the link will expire in few days should be enough to watch it...
  12. M

    help with ecoTEC valliant 831 and heating

    I have used the lowest part of drain, connected hose and started opening the air vents from top floor down, I have used wet / dry vacuum as well to suck remaining debris from this radiator, and I have done it at the other drain as well as I have couple in the house, I have as well opened with...
  13. M

    help with ecoTEC valliant 831 and heating

    I think the sensors are top left corner, there is a blue clip and red clip so I guess red will be flow and blue return. So the return sensor is on the hot part of the pipe, the return pipe inside the boiler is hot if that make sense, the return pipe below the boiler is lukewarm. In terms of...
  14. M

    help with ecoTEC valliant 831 and heating

    so I have set the D.000 partial load: auto D.014 pump speed target value: 100% D.015 the actual speed is showing as 100% D.019 function mode of 2 speed pump: stage 2 , I tried as well on CH auto and DHW 2 it seems more stable now in terms of the boiler shutting down and cycling there is still...
  15. M

    help with ecoTEC valliant 831 and heating

    Is there a magnetic filter installed close to the boiler, on the return. - yes there is filter on the return pipe I have empty it few months ago before I have put x400.
  16. M

    help with ecoTEC valliant 831 and heating

    I'm trying to balance the radiators again opened all the valves to check which radiators heat first and have those settings on the boiler D.000 partial load: auto D.014 pump speed target value: Auto D.015 the actual speed was showing as 15% D.019 function mode of 2 speed pump: stage 2 , I tried...
  17. M

    help with ecoTEC valliant 831 and heating

    not sure how to tell if the boiler is or its not cycling as I'm not heating engineer just the owner is there any live stats which will tell me? Are all the rads heating up properly apart from 1 or 2? - yes I can make all the rads heat up expect this one in the hallway, I can make it to heat...
  18. M

    help with ecoTEC valliant 831 and heating

    I did drain the the system to flush the x400 and refill with fresh water and added inhibitor I run initially around the house with all radiators fully open to check which one heat up first make note and tried to balance with the ones heating up first turned just a quoter and the rest opening a...
  19. M

    help with ecoTEC valliant 831 and heating

    Hi I hope someone can help with my heating which drives me crazy for the past few years, I moved in 2019 so I don't have the history how the heating was working in this house in the past year boiler installed on ground floor ecoTEC 831 installed in 2013 according to the service papers I have 15...