    cold radiators down stairs. was only 1 now 2 following flush

    HI THERE, SORRY, BUT IF YOU HAD AN EFFECTIVE POWERFLUSH YOU WOULDNT BE ON HERE HERE NOW, COS POWERFLUSHING GETS RID OF ALL MAGNATITE IF DONE EFFECTIVLEY. DAVE 18 HAVE A RE THINK MATE?????? AGREE TOTALLY WITH POWERFLUSH COMPANY, TOO MANY ENGINEERS ARE QUICK TO DISMISS SLUDGED UP SYSTEMS AND...
  2. B

    Tests after Boiler repair?

    ALSO, NOT CO2 TO BE WORRIED ABOUT UT THE CO!!!!!!!!!!!!!!
  3. B

    Tests after Boiler repair?

    WHAT IF YOU FIT THAT FAN BUT PUSH OR BREAK A SEAL WITHOUT KNOWING?? OR THERE IS AN EXISTING FAULT WITH COMBUSTION AND EVERYTHING LOOKS OKAY??????????YOU........ ARE THE LAST ENGINEER TO AFFECT COMBUSTION!!!!!!!!!!!!!!!!!!!!!!!!!
  4. B

    Glowworm BG 330 boiler

    GAS SAFE REGISTRATION ONLY DEEMS SOMEONE TO BE SAFE TO WORK ON GAS!!!!! FAULT FINDING SHOULD BE A SEPARATE CATOGORY COS FITTING BOILERS AND WORKING ON THEM ARE COMPLETELY SEPARATE AREAS OF GAS AND THEY SHOULD ONLY BE WORKED ON BY THOSE WITH THE THE KNOWLEDGE. SORRY TO BE RUDE MATE BUT, YOU...
  5. B

    Tests after Boiler repair?

    WTF!!!!!!!, IF YOU'RE CHANGING A FAN THEN YOUR AFFECTING THE COMBUSTION PROCESS SO, YOU NEED TO CARRY OUT A COMBUSTION TEST TO MAKE SURE THAT ALL IS WELL AND ALSO A GAS RATE(0 GOVERNOR BOILERS) IS REQUIRED. CAN ALL YOU DIS BELIEVERS, IN DOING SO, REALLY FEEL CONFIDENT IF WHEN THEY FIT A FAN...
  6. B

    Radiator not getting hot

    systems should be balanced when installed and should only really require re ballancingif system loads change
  7. B

    ISTOR HE 325 BOILER FAULT - PROBLEM

    sorry, forgot to answer your Q, basically when display is blank it's either simply your display pcb or your main pcb but what we find quite commonly is if it is the main pcb its because there is a water leak in the combustion chamber and drips down onto main pcb so ,even if you change it it'll...
  8. B

    ISTOR HE 325 BOILER FAULT - PROBLEM

    hi, just to add to last comments, i am a bg engineer and we go to masses of this range of ideal boilers and guarantee you will have lots of breakdowns, sorry to be the bearer of bad news!!!!
  9. B

    boiler makes loud bang

    hi there, cant be issue with boiler as that operates in an equal way to when either heating or hot water is called for, so i agree it must be a valve issue!
  10. B

    Radiator not getting hot

    hi mate. i'm new on here and have read your posting, just thought i'd mention what no one has said,, if you've not altered your boiler or system in any way at all since installation and are now getting circulation issues, then clearly it's either your pump is wearing down and is not as powerful...
  11. B

    Downstairs radiators not heating :-(

    Hi there, pump would be the first to try if there has been no intervention to boiler or system while working ok to being faulty.