Search results

  1. D

    blocked gas lines

    today I was at a breakdown which was caused by a blocked filter in the gas valve. I am from N IRELAND, i THINK WE DONT HAVE ANY FILTERS ON THE PIPELINES. Can you get filters for a domestic premises. Has england got any filters. what would you advise..
  2. D

    no CH, have HW, Pump scolding, pilot will not light!

    Did you drain down the system. Is all the valves open. Bleed the water pump, is the water coming out..
  3. D

    open vented system over pumping

    On friday i am going out to a system that is over pumping for 2 years. The installer has fitted the waterpump after the fill and ex pipes, on the neg side of the system. ALso a bypass valve fitted. Open for comments
  4. D

    sime oil boiler locking out (flue problems)

    I have a sime boiler c/w a nu-way nol3 which is top class shape. I know that is a flue problem, It will lockout once a month in the moring time. I have measured to draft cold and hot -reading cold +1 mbar -reading hot -4mbar. Any tips oilman?
  5. D

    EXPANSION TANK OVERFLOW (REQUIRE TECH INFORMATION)

    I recently carried out a survey on a heater system and found several faults. One of the defects involved the expansion tank. Details : The expansion isnt covered and the overflow is piped looking into the storage tank. E.g If the expansion tank was to over fill it would overflow into the...
  6. D

    Is it mdpe gas pipework

    I am currently servicing boilers in 3 flats. The meters are installed inside the flats. The Service Pipework Runs up the side of the building externally. At ground level the service pipework coming out of the ground is a yellow plastic pipe (mdpe) If is about 3foot tall before changing in...
  7. D

    anybody know a boiler manf called Benraad

    I am looking information on Benraad boilers.
  8. D

    WATER BY LAW (FILL LOOP)

    Thanks for the feed back. Has anybody done any sealed system course?
  9. D

    WATER BY LAW (FILL LOOP)

    In all my books and boilers manuals about Fill Loops on a sealed systems, It advises you to remove the flexi pipe. Yesterday I was told that as long as there is double check valve installed you can leave the flexi connected. Most sealed sysytems always have the mains turned off , but the...
  10. D

    Powermax 155 Combi - no hot water

    It could be a number of thing, have you cold water supply, insure that the valves are open under the boiler. Your plumber should be able trace the water to the boiler. Good luck.