  1. M

    firebird heatpac

    Hi Thanks for reply Yes spot on no lights on pump and 240v going to it . Looks like water has dripped from exchanger onto it !! Next problem is sourcing a new head Grundfos HE UPM3 15-70 103 Local shop has an ALPHA head any idea if this l will this be ok ? Thanks again Steve
  2. M

    firebird heatpac

    Hi All woke up this morning and my heating isnt on. Boiler heating light is on ,but boiler isnt doing anything.I switched on hot water at controller and boiler fired up briefly then shut down ,both hot water light and heat light are now on .I cant hear pump running .Could this be the...
  3. M

    firebird heatpac suddenly loses pressure

    Took boiler up to 2.5bar found a tiny leak on heating circuit connector on bolier repaired that . Seems to be holding 1.5 bar now .I still have air getting into highest rad though. Every day i get about 1seconds worth of air out of it . Ive gone thru all other rads and no air in...
  4. M

    firebird heatpac suddenly loses pressure

    Hi all i fitted a heatpac recently all seemed well until one day pressure dropped to zero .Now if i charge it ,it can stay constant for weeks ,then suddenlt loses all pressure ,not gradually ,basically it can go from 1.5bar to zero overnight. No visible leaks checked exp vessel...
  5. M

    boiler over pressurising

    heads up. it was plate heat exchanger. symptoms sounded like expansion vessel . live and learn
  6. M

    boiler over pressurising

    Ive isolated heat exchanger .it has a valve just before exchanger on water inlet . Had heating on for 2 hours and its steady at 1.2 bar .I think its heat exchanger ! live and learn . Thanks for all the replies
  7. M

    boiler over pressurising

    Hi charged to 1bar before fitting. i wonder if it could be heat exchanger ?
  8. M

    boiler over pressurising

    Hi yes did that this morning
  9. M

    boiler over pressurising

    Hi all odd one here. Firebird enviromax boiler . was gaining pressure up tp 3 bar . to point where safety valve was opening. Fitted new expansion vessel 12 litre same as original. Still happening . dropped pressure back to 1bar via safety valve still keeps rising Thought maybe...
  10. M

    Riello burner 240v at cont box nothing happening

    I replaced cont box then it went to purge mode. so cont box was def faulty.(my old one did nothing) i then disconnected my original pc and it fired then locked out indicating bad pc. went and got a,new one but bought digital one by mistake. have analogue one coming tomorrow from amazon...
  11. M

    Riello burner 240v at cont box nothing happening

    there are 2 photo cells the old one is anologue. it goes with rdb cont box with red reset button (mine) the later box uses a digital pc . looks identical but doesnt work with older box. the new box has a clear reset button .
  12. M

    Riello burner 240v at cont box nothing happening

    thanks all . school boy error. new pc is digital. my old one is analogue! new one coming tomorrow. watch this space. going to have to be a cold shower today .3 days is enough !!
  13. M

    Riello burner 240v at cont box nothing happening

    well kind of making progress! fitted new box . just purges constantly no spark or flame . pulled photo cell . fires then cuts out . so looks like maybe the old control box took out the photo cell maybe ? . anyway went and collected a photocell from local shop looks the same but fires then...
  14. M

    Riello burner 240v at cont box nothing happening

    replaced cap. still dead! waiting for new control box to arrive
  15. M

    Riello burner 240v at cont box nothing happening

    ive got a,new cap coming as its definitely ou of spec. we shall see. cheers guys
  16. M

    Riello burner 240v at cont box nothing happening

    ive just switched it on with pc disconnected still dead :(
  17. M

    Riello burner 240v at cont box nothing happening

    Hi it doesnt even attempt to fire its totally dead . is it still valid to to the photo cell test .
  18. M

    Riello burner 240v at cont box nothing happening

    correction! just realised my fluke meter has a capacitance setting! its reading 2.7uf. it should be 4.5. would that cause motor to not run ?
  19. M

    Riello burner 240v at cont box nothing happening

    thanks again. ive checked cap with my digital meter. not as good as using a needle type .but seems to be checking out ok .
  20. M

    Riello burner 240v at cont box nothing happening

    Hi just checked diagram limit stat and safety thermostat are both in live line to box .i have 240v at box so no its not that. Cheers