    Grundfos ups3 15-50/65 130 fails as replacement for old Grundfos UPS-15-50 Selectric

    Did you try increasing pump speed on new one?
  2. D

    Grundfos ups3 15-50/65 130 fails as replacement for old Grundfos UPS-15-50 Selectric

    Air lock, try turning gas off at boiler, Turn system on and alternate pump speed settings to shift air away from the boiler
  3. D

    Domestic Flights Identification

    Apparently you can still hold a driving licence with mono vision. So you could keep your licence and not drive if not confident
  4. D

    Quality Cookware

    Try Stella pans, we have had ours for over 20 years . They are really good quality and easy cleaning
  5. D

    Upstairs Flat Supplying Downstairs Flat DHW - Combi Boilers combined?!

    You may have a pre heat hot water on your boiler, it will come on at random times , What make and model is your boiler?
  6. D

    Internal Concrete Floor Height vs DPC

    Finish above floor, fixings for skirting
  7. D

    Row of tiles in front of dormer

    And the condese pipe from boiler is wrong size and a mess
  8. D

    Is the back of this shelf hanging over the edge?

    Please don't be offended but I cannot believe you actually get paid for work when your level of construction and experience is so limited
  9. D

    Leaks in copper pipe…..

    Have the earth checked by a electrician, it has been said that a bad connection may cause pinholes in pipe work
  10. D

    buying small parcel of Land from the council.

    How did the pile of rubble get there if access is only through your land?
  11. D

    What have you been doing today?

    Congratulations to all the family
  12. D

    Vents in kitchen cupboard door for boiler

    You may need compartment ventilation, check the manufacturers instructions
  13. D

    Will a non-reverse valve cause a pipe to burst when blocked and what's the likelihood

    Pretty sure your waste pipes are 40mm, this is undersized. A vent pipe is a pipe on the system that is taken high up and left open. If no vent is installed it can create a vacuum on the system and you have trouble with the water not discharging properly. Maybe worth taking to the freeholder if...
  14. D

    Worried about this

    18 KW boiler requires approx 1.8 cubic metres of gas . 15mm copper pipe at 3 metres length, capable of discharge of approx 2.9 cubic metres
  15. D

    Worried about this

    I would have run it in 22mm . However it will not be a problem regarding pressure drops etc
  16. D

    Will a non-reverse valve cause a pipe to burst when blocked and what's the likelihood

    Pipe work looks undersized. Would also help if it was vented high up
  17. D

    Damp problem possibly caused by leaking drain. Any advice?

    It could be possible to do a air pressure test, or maybe a bung at manhole and water test depending on pipework
  18. D

    Twin Flu

    No, very costly to run unless you have a super insulated property.