Search results

  1. D

    Honeywell TRV valve numbers?

    Balancing adjustment
  2. D

    Did you get your booster?

    Really sorry bod,
  3. D

    Hot water tap very hot

    Cylinder thermostat to low.
  4. D

    Potterton Kingfisher Mf - extinguishing and not re-lighting

    If you have in excess of fifty years experience working on old boiler's I am surprised you are asking for advice
  5. D

    Boiler combustion readings high

    What was the combustion reading's. Should ask for a gas rating, burner pressure and condition of flame picture. Technically do not have to use flue gas analyser on standard efficiency boiler
  6. D

    What a thicko

    Unnecessary , what happened to isolating.
  7. D

    Leaking toilet waste pipe query

    The seal at the end connecting to the pan should be inwards
  8. D

    Moonlighting Gas Fitter

    Obviously aware of that. was responding to comments regarding having it serviced and then issuing a gas safety record
  9. D

    Moonlighting Gas Fitter

    Tightness test not legally required for landlord cert. You can buy a u gauge to test gas but do you know about letby , temperature stabilisation, and the permitted losses depending upon type of meter .do you have access to a fga and are familiar with the co/ co2 ratios to say that it is...
  10. D

    Moonlighting Gas Fitter

    Tightness test not legally required for landlord cert. You can buy a u gauge to test gas but do you know about letby , temperature stabilisation, and the permitted losses depending upon type of meter .do you have access to a fga and are familiar with the co/ co2 ratios to say that it is...
  11. D

    Can anyone tell me what this bit circled in red is called? Gas Meter leak

    Dan. Don't be a p you might need a sock off Jeff. In the cc
  12. D

    Can anyone tell me what this bit circled in red is called? Gas Meter leak

    Dan I am well aware of what needs to be checked at the meter on a install. My point was that the meter is external and could have been tampered with.
  13. D

    Can anyone tell me what this bit circled in red is called? Gas Meter leak

    Who's to say that the rgi left it off. The meter box is external
  14. D

    Ideal Isar HE24 hot water woes

    So you have had a trouble free 5 years and now it's a terrible boiler
  15. D

    Been told I need a new boiler...?

    Keep the boiler and sack the engineer. Looks like leak on diverter. Parts are available
  16. D

    Continuity bonding gas meter removal nvq level 3 question

    Upstream /downstream, when connecting, reverse when disconnecting
  17. D

    UKPF survivors group

    Grouch, enjoyed his post in cc, think he ****ed off some knob heads in general forum
  18. D

    Booster pump or mains pressure tank.

    Increase heigth of cold water storage cistern in loft
  19. D

    Fitting a new external expansion vessel

    The post was in jest, you have had advice on here from some very knowledgeable plumbers/rgi.
  20. D

    Fitting a new external expansion vessel

    Put it very high up in the loft, vent by taking cap off and depressing schrader valve
Back
Top