  1. H

    Boiler Diverter Valve

    You could turn off one or both of the heating isolation valves as a temporary fix while you get it repaired.
  2. H

    Valiant ecotec 637 pressure sensor playing up?

    Sound like the expansion vessel is flat which is not uncommon with Vaillant boilers.
  3. H

    Central heating not automatically working (hot water ok)

    Have you checked the room thermostat has voltage when you select CH at the programmer ?
  4. H

    boiler turned off by an engineer

    It all a load of ballcocks, take a look at the later Vaillant Ecotec boiler for example and compare it with the early Ecomax E model, much the same layout but the 613E, 824E and others have a massive cutout in the front casing to accommodate the black plastic control box which just rest up...
  5. H

    boiler turned off by an engineer

    Suck or Blow, inside the outer casing is negative (Suck), inside the combustion chamber is positive (Blow) you would have to go back to the Potterton Netaheat to find positive pressure inside a boilers outer casing.
  6. H

    boiler turned off by an engineer

    So very true but those same tw@ts are now running the show.
  7. H

    boiler turned off by an engineer

    I have worked on thousands of Vaillant boilers and never seen it unless the flue seals are perished or damaged and then CO readings are fairly low if they were off the scale as your suggesting the boiler would lock out every time. Also I might add a plenum chamber is at a pressure above...
  8. H

    boiler turned off by an engineer

    Technically putting 4 self tapping screws into the holes which are there for the badge could be considered as modifying an appliance if you wanted to be really anal about it and yes there are those who would RIDDOR you for doing so. I came across a contracts manager for a large company who...
  9. H

    ideal Mexico - CH working but not HW

    How simple it is to convert is very much down to your personal skill level, an experienced engineer would think its fairly easy, you need to know your limits when it comes to DIY as its often cheaper in the long run to employ a professional. I questioned your understanding of your system from...
  10. H

    ideal Mexico - CH working but not HW

    Was the system full of sludge when you first drained it? How long is it now taking to heat a full cylinder? How does it compare with the time it took before? I still think your best move would be to convert your system to fully pumped and get all the benefits that would give you.
  11. H

    How to best turn off the boiler at night

    Hi Claudia, have you not got access to a smart phone as photos or a video of the plumeing taking place around your window could only strengthen your case, but its more likely to be seen when the weather is colder just like a car exhaust is. The system pressure has absolutely nothing to do with...
  12. H

    ideal Mexico - CH working but not HW

    Thats normal with a gravity HW system, your boiler can heat the water faster than the indirect coil can exchange it to your DHW, it may take an hour + before the water in your cylinder is up to temperature, longer if lime scale has built up on the coil over the years.
  13. H

    Recharge expansion vessel on CH

    Did you get 0.8 bar when the system was full (pressurised)? You should have around 0.9 when your system is de-pressurised, it makes a big difference.
  14. H

    Silly questions!

    Many boilers will lock out if the pressure drops below 0.8 bar so it might be a good idea to top yours up to 1.2 (when cold) using the filling loop.
  15. H

    Silly questions!

    1 to 1.2 bar is normal when cold, if pressure drops below 1 it needs topping up this should happen no more than once or twice a year unless you need to bleed your rads excessively.
  16. H

    Silly questions!

    Hi, the pressure rise and fall is down to the expansion of the system water, as it heats up it expands more, most of this expansion is absorbed by the expansion vessel, if the pressure starts to go much higher than 2 bar its probably an indication that the air pressure in the expansion vessel is...
  17. H

    Recharge expansion vessel on CH

    De-pressurise you boiler and leave drain cock open while you charge up your expansion vessel to that stated on data plate, normaly around 0.9 bar, close off drain cock, re-pressurise & vent system.
  18. H

    Can You Use 'Just For Copper' Adhesive On Gas Pipes?

    Just watched a Youtube video from Allan Hart "How to Solder Copper pipe without a flame UK" he uses a product called Super Power and its approved for gas, what do you think?
  19. H

    How to dismantle part of the Diverter Valve.

    Looks llike it what we thought all along but I expected there to be a small O ring, good luck with everything.
  20. H

    How to dismantle part of the Diverter Valve.

    If your system pressure is dropping as a result of the leak then the leak is from the diverter valve.