  1. H

    Drayton MA-1 valve problem.

    Have you got a 230 volt supply to the synchonous motor when you select CH, if you have and the motor doesn't drive over then a new motor is reqd, always check with a multimeter.
  2. H

    Grundfos 15/60 and Myson Unit 5 same?

    Yes but be aware, modern pumps are designed for modern systems so no pumps are best suited to your gravity HW system so make sure you give it a fews minutes run EVERY week during the summer months otherwise you will find it wont work when the weather changes and you need your central heating.You...
  3. H

    ideal Mexico - CH working but not HW

    NO because that is your heating pipe, the pump does not work when you just have hot water on. the pipe in your blue box will get hot only when you have heating on also.
  4. H

    ideal Mexico - CH working but not HW

    You said eveything filled up & vented OK and the rads get hot therfor you can rule out a blocked cold feed and your pump must be OK or you ground floor rads wouldn't get hot your upstairs might get hot without the pump if there is no vertical or horizontal check valve fitted, you also say its...
  5. H

    ideal Mexico - CH working but not HW

    Just remember, air will always rise the the high points just like the bubble in a spirit level unless you have means to release that air you have a problem, look for those high points, the coil in the cylinder is one and can prove difficult to remove, many of us heating engineers have our ways...
  6. H

    ideal Mexico - CH working but not HW

    And that rad is on & vented?
  7. H

    ideal Mexico - CH working but not HW

    So its a soldered cap then, if it was a compression fitting you could just loosen it a bit to release the air.
  8. H

    ideal Mexico - CH working but not HW

    Just to be clear I mean the pipe that goes up & is painted, I assume that your cold feed pipe is in the cylinder HW return as it a bit difficult to see in yor photo.
  9. H

    ideal Mexico - CH working but not HW

    If its a capped off pipe is there any means of releasing air from it?
  10. H

    ideal Mexico - CH working but not HW

    Turn your CH off and HW on, turn your boiler thermostat to MAX this might force the air out of the open vent.
  11. H

    ideal Mexico - CH working but not HW

    Where does the 1/2" pipe which is tee'd out of your HW flow (Side top connection) to your cylinder go?
  12. H

    ideal Mexico - CH working but not HW

    The pipe on the left of boiler is HW flow the pipe on right hand side with pump is CH flow.
  13. H

    ideal Mexico - CH working but not HW

    So have you got a second pump for the CH system?
  14. H

    ideal Mexico - CH working but not HW

    Your picture shows the pump fitted in the HW return, can you check as it should be in the CH.
  15. H

    ideal Mexico - CH working but not HW

    As said by others you probably have a gravity HW system, if so you will NOT have a thermostat strapped to the side of the HW cylinder and your pump wont run when you select HW only, is that the case?
  16. H

    What's this part called and should the black bit be tight?

    Then it NOT an auto air vent, may as well fit thumb vents as much cheaper and they call them manual vents
  17. H

    Is it safe to leave central heating system empty?

    Probably wouldn't make any difference if system was drained or not, valve might get tight due to lack of use long-term.
  18. H

    Pump speed/Automatic bypass valve setting.

    Im not arguing with you but the OP said his pump is the standard 3 speed model so what is the pump curves going to tell us?
  19. H

    Is it safe to leave central heating system empty?

    I Remember many boilers that were not used in the summer months suffer from a thick layer of fine rust dust on the burner top so make sure you get it serviced when its reinstated.
  20. H

    Is it safe to leave central heating system empty?

    How long are you talking about as many systems go 6 months without the motorized valve operating.