Search results

  1. A

    Main 24he no heating, even after pcb swap

    Hi, Yes I did measure voltages across the stat terminals and I have 230. I am an electrician so I am quite confident in following the fault flow chart.
  2. A

    Main 24he no heating, even after pcb swap

    Thank for the replys. That was the first thing I checked. External controls are fine, to be 100% I even linked out the terminals. The pump isn't running, there is no power to terminals 15 and 8 on M1 connector (live and neutral) Boiler fires up and pump runs on DHW.
  3. A

    Main 24he no heating, even after pcb swap

    Hi guys, Fired up heating after a long while out of use and it didn't fire up. Going through the f/f process I got far as checking the power to the pump. No power, change pcb. As it happened I had a new pcb for emergencys, fitted this and still the same problem?! Any ideas? Heating...
Back