    Vaillant diverter valve Improved design?

    No troubles. The cover has been reinstalled with no problems. I'm just curious to know how many covers fail to seal properly. How many Vaillants similar to mine have you known the front cover fail to seal properly?
  2. J

    Vaillant diverter valve Improved design?

    I thought it would be the end of the thread after I posted about doing the job satisfactorily but you guys decided to jump on me again :mrgreen: So no explanation on how I'm clueless about the pressure vessel? It will be serviced as it is overdue. The only gas related item that has been...
  3. J

    Vaillant diverter valve Improved design?

    I think you're thinking of Nat King Cole's 'Let's face the music and dance' The lyric is actually 'there may be trouble ahead' Why do you think there's trouble ahead? I have followed the manual to the letter so what's the problem. I'm not expecting an answer because I know you're just...
  4. J

    Vaillant diverter valve Improved design?

    What was I warned about? As I've already said I've completed the job and all is good so what's the problem? I'll tell him exactly what I've done and if he's got an attitude as bad as you lot I'll ask him to leave my house. So you can't even describe how you think it works after accusing me of...
  5. J

    Vaillant diverter valve Improved design?

    Please explain how it works then Why am I going to have problems? What would you have done differently?
  6. J

    Vaillant diverter valve Improved design?

    Surely recharging it is only going to take it back to it's original position though if it's at the correct pressure to start with so how does that push more water out? I only recharged mine last week. I pressurised it to the Vaillant maximum recommended pressure of 0.9 bar. I'm guessing the...
  7. J

    Vaillant diverter valve Improved design?

    How does the PV retain water? Surely it just drains out whilst you're draining the system down? Or does it only retain water if it's not properly pressurised? Does the diaphragm fully expand to the whole volume of the PV when you drain the system when fully pressurised?
  8. J

    Vaillant diverter valve Improved design?

    If I had drained the DHW instead of the CH I would of got very wet! I didn't turn the water off either.
  9. J

    Vaillant diverter valve Improved design?

    It's not connected to the DHW. It's just the straight on angle of the picture making it look that way. It's connected to the 22mm CH pipe. There is no drain cock on the hot water pipe. The only drain cock is on the CH pipe
  10. J

    Vaillant diverter valve Improved design?

    I thought I'd give an update. I've changed the diverter valve and you'll all be very disappointed to know there was no spraying of water anywhere and I didn't even get wet in the slightest. I closed all the TRV's/valves and then cracked open the drain cock and left it for about half an hour...
  11. J

    Vaillant diverter valve Improved design?

    The motor looked to be winding in and out OK when I had it off. I guess it could be the PCB but the fact that mechanical intervention makes it start working again definitely points to the valve or motor. The new diverter valve comes with a new different type motor so I'll see what happens when...
  12. J

    Vaillant diverter valve Improved design?

    Also the CH and DHW worked perfectly for a day after I played around with it and is working perfectly again after a second fiddle. Correct me if I'm wrong but the CH and DHW wouldn't function correctly if the motor wasn't attached correctly.
  13. J

    Vaillant diverter valve Improved design?

    I've said this a few times now Yes definitely. I adjusted the motor as far back as possible whilst still being able to latch it back onto the plunger to make sure it was pulling the plunger as far back as possible.
  14. J

    Vaillant diverter valve Improved design?

    I'm guessing the lack of a reply means you agree with me?
  15. J

    Vaillant diverter valve Improved design?

    It wouldn't have been changed recently. I am planning on getting the boiler serviced as it is overdue. I will ensure it is changed.
  16. J

    Vaillant diverter valve Improved design?

    I'm pretty confident it's the diverter valve. It's been playing up for months now but I always thought it was the shower. As soon as I started playing with the diverter valve I started getting full temp DHW with no diversion into the CH system. It worked properly for a day then started...
  17. J

    Vaillant diverter valve Improved design?

    I'm willing to listen to advice. I just can't be doing with people trying to shoot me down because I'm doing the work myself. At the end of the day I know the risks and I'm old enough and ugly to make up my own mind. Its an Ecotec plus 824 VUW GB 246/3-5.
  18. J

    Vaillant diverter valve Improved design?

    OK then. Try being helpful for once. How would you suggest I drain the system down?