  1. Alarm Engineer

    HKC vs Orisec alarms

    I’ve never come across HKC equipment before but I understand they have been around for some time. Orisec however is a very new company but they have a great panel and it’s been designed by people who have previously developed some of the best alarm panels on the market, past and present. So...
  2. Alarm Engineer

    Euro 46 / mini. Programming a zone.

    You can’t, it’s a code set by the installer & it’s unlikely that the installer will give it out. You have two options either contact the installer, pay them to reset the code to 1234 for example. Or default the control panel to factory settings & reprogram the entire system from scratch.
  3. Alarm Engineer

    Euro 46 / mini. Programming a zone.

    Go to change inputs, type in the Zone number and press yes to edit the Zone and it will show the areas it’s in AB etc so just press B to add/remove it.
  4. Alarm Engineer

    Euro 46 / mini. Programming a zone.

    Remove B from the zones you want OFF at night. Find out what panel you have by going to software Revision
  5. Alarm Engineer

    Image Command for HiWatch IPC-D120 Camera

    Hi, I’m trying to connect a test bench camera into my Texecom Connect App and need to confirm the image command. Camera is a IP HiWatch IPC-D120 Made by Hikvision and i’m using the following command. /Streaming/Channels/101/picture Can anyone confirm this is correct?
  6. Alarm Engineer

    Pyronix enforcer communication error beeping

    I think is a fault caused by initally powering the system up incorrectly. Power system down completely (mains-Battery) & re-apply power.
  7. Alarm Engineer

    Pyronix enforcer communication error beeping

    Whats displayed on the screen? Is it connected to a communicator? If not then disable Digi/SMS. If you are connected are you recieving signals & what type of coms are you using?
  8. Alarm Engineer

    Euro Mini Hard Reset

    Clean start is only available in the engineer menu. The different codes 2000, 2001,2001 will all work albeit certain programming features will automatically configure to comply with standards.
  9. Alarm Engineer

    Euro 46 mini? 485/comms lost

    Yeah its in the metal box. Replace with a 12v 7ah type if its not already, some people fit a smaller 3.2ah type. The lower the ‘ah’ the shorter the standby time in a power cut. When opening the box, the system will go into Tamper alarm, enter code to silence, change battery, put lid back on the...
  10. Alarm Engineer

    Euro 46 mini? 485/comms lost

    The battery should be lasting around 7-9hours without electricity before parts to fail, if not you either have a duff/expired battery (change every 4years) or there is too much load on the system and therefore an additional power supply would need to be fitted to split the load and prolong...
  11. Alarm Engineer

    Euro 46 mini? 485/comms lost

    Press No & enter your normal user code or present keyfob if you have one, repeat a couple of times, should clear the fault & reset. Sounds like you’ve had a power cut & maybe the backup battery died.
  12. Alarm Engineer

    Euro 46 mini? 485/comms lost

    If its the only keypad, Press & hold D until display shows ‘enter security code’ enter 2000 and ensure the Address is set to 00 then press A. If this dont work you have a cable fault/disconnection. Is keypad powered from control panel or is there another power supply?
  13. Alarm Engineer

    Euro 46 mini? 485/comms lost

    Yeah it goes into Tamper.
  14. Alarm Engineer

    Poor water pressure (now fixed)

    The Aerators, Swapped the Kitchen sink one for the Bathroom one tonight & the seemingly low pressure followed. Bathroom one was full of sand even though I had cleaned it out recently. Ordered some new ones, should be alright after that.
  15. Alarm Engineer

    Poor water pressure (now fixed)

    Sorted now, thank you.
  16. Alarm Engineer

    Euro 46 mini? 485/comms lost

    Some earlier versions do this when exiting the keypad menu.
  17. Alarm Engineer

    Poor water pressure (now fixed)

    Nope, nothing like that around.
  18. Alarm Engineer

    Poor water pressure (now fixed)

    Not entirely sure, think its a combi boiler. No tanks or cylinders. Sorry i’m usless with plumbing hence i came here.