    FORTIC cylinder low flow

    hi CrisR all above now installed and working fantastically well, now have power shower,bath,basin,kitchin sink with header tank remaing wet so no ingress of air even when running bath,:lol: whilst fitting this the reason for the low flow was found, boss white near blocking the 22mm compression...
  2. R

    FORTIC cylinder low flow

    hi CrisR found the part an essex flange 22mm i'm thinking one of these to supply the pump-22mm pipe - bath & basin taps,the pump is 15mm showerforce sonic with variable boost control hopeing this will boost the low flow more than 4 ltrs a min, what say you.
  3. R

    FORTIC cylinder low flow

    hi'ya CrisR thanks for the reply as you say the risk of sucking air could be a problem that i'm hopeing overcome with a fitting that goes into the main top part of cylinder makeing a new outlet flow when i find out what this part is called and obtain one, if you have any info i would gratefull.
  4. R

    FORTIC cylinder low flow

    hi johnD the flow rate from basin & bath taps = 4 litres/min
  5. R

    FORTIC cylinder low flow

    hi'ya thanks for speedy responce hope this makes some sense to yer ! what sort of bath tap have you got? = single x 22mm pipe connections but outlet looks smaller Is it a mixer? Is it Italian? = no, not known does it have a flexible connector? = no, 22mm copper to tap...
  6. R

    FORTIC cylinder low flow

    Help please, suggestions how to improve the flow from a fortic cylinder mounted 7ft 8in to top of header tank, with 22mm flow pipe X 28ft to bath & taps in a flat with 8ft ceiling. considering fitting a power shower pump to improve flow to bath, this being max demand. thanks in advance for any...