    Not Getting Hot Enough!

    Thanks for that desktop. Yes a circulation issue does seem to be the consensus and will investigate with my plumber. The only thing is, I thought the boiler temperature would need to be much higher say 80 or so for it to short cycle. Can I be sure the boiler is working ok?
  2. N

    Not Getting Hot Enough!

    No afraid not. Pump was changed to try to fix the problem. It was quite old and becoming very noisy anyway.
  3. N

    Not Getting Hot Enough!

    No I don’t think so ericmark. I have a Salus IT500 smart thermostat and the room never gets anywhere near the set point as I set it high to ensure the boiler keeps firing if it can, I.e to investigate what is happening. Temperature does not generally get above 19.
  4. N

    Not Getting Hot Enough!

    Thanks Madrab. Downstairs (7 rads) is 22mm. Upstairs (5 rads) is 15mm as this was done as a chalet bungalow extension. Flow pipe temp is around 64 max. From boiler in kitchen the pipe goes to the 3 way valve in the airing cupboard which is downstairs about 7m away. Hot water cylinder is about...
  5. N

    Not Getting Hot Enough!

    Further to my last post I monitored the boiler during Monday to see if there is any pattern in what it is doing. Boiler control set at 75%. The heating is set to come on from 6am to 11pm. Demand is continuous as the room thermostat never reaches temperature. The water comes on from 6 to 8am, 1...
  6. N

    Not Getting Hot Enough!

    Thanks again guys. I believe the radiators are average size although there are 2 doubles. I don't think the pump replacement made any difference apart from being much quieter. However I did not notice what the boiler was doing before we changed it. If the boiler cannot move the heat, could...
  7. N

    Not Getting Hot Enough!

    Thanks guys. I have tried putting the heating control to max. This helps in that the radiators now range from 46 to 56 (with a bit more balancing) but not as hot as they should be I think. The pump is a brand new Grundfos UPS4 Go. The motorised valve seems to be working correctly. I would...
  8. N

    Not Getting Hot Enough!

    Hi there. I have a Greenstar 24RI boiler and a gravity system with a hot water tank on the ground floor. I have an extended chalet bungalow, 7 radiators downstairs and 5 upstairs all with TRVs. Boiler is 7 years old and just had a new pump as old one was very noisy. Struggling to get house up...