  1. E

    Wireless Alarms

    Why would you have the alarm set whilst at home playing home theatre ?? The reviews I found seemed generally good, but thanks for feedback.
  2. E

    Wireless Alarms

    Oh. Are they unreliable ?
  3. E

    Wireless Alarms

    I know they seem to be despised on here, but I have yet to see any valid reasons or explanations why ? Anyone tried/had problems/any feedback on the Visionic Powermax system ?
  4. E

    Max Zs please...

    Alteration or addition ? Is the circuit protected by an RCD?
  5. E

    Optima Compact/Defender Bell Box

    Wow, obviously mr unpopular then, 33 views and no replies ! Sorthed it, it was a faulty external siren.
  6. E

    Optima Compact/Defender Bell Box

    Hi, I've wired one of these, dead simple (should have been) just two PIRs and an internal speaker. Couple of problems: 1) When putting the battery jumper to "ON" on the bell box, the siren sounds, but remains on even with cover back on. Stays on even if hold tamper switch closed manually...
  7. E

    Advice on CU change where switch drops are unearthed

    Stilll waiting chri5 ....
  8. E

    Max Zs entry on EIC for an RCD circuit

    SS, Yes, table 41.5 is in the section for TT systems. However, as pointed out earlier it is referenced to from the TN systems section (411.4.9). BS7671 isn't telling you enter the value in table 41.5 as the maximum permited, niether does it say anywhere that the value in any other table or...
  9. E

    Max Zs entry on EIC for an RCD circuit

    Many of the figures given in tabulated form are not exactly the same as the calculated value. Consideration will have been given by the authors (I assume) to this figure and deemed acceptable given that it is 0.01V above the calculated value. As the content and values of BS7671 are not...
  10. E

    Max Zs entry on EIC for an RCD circuit

    Garymo/Spark123 you seem to have completey missed the point. My OP relates to the entry on the EIC for a maximum value, not what you measure, what is wrong, what you expect, what you would be happy with, what is acceptable or whatever. What's it matter ? I think it matters that an EIC is...
  11. E

    Max Zs entry on EIC for an RCD circuit

    No not having a dig at you. My facts are right. I said you were entering incorrect data on the EIC for maximum Zs permitted. This is because you were not entering 1667, you were entering some other value, which is not the maximum. You were then applying a correction factor to this value for...
  12. E

    Max Zs entry on EIC for an RCD circuit

    Sounds better ? why ? Its written in black and white in the regs so how can it be wrong ? Because its .01 V above V=IR <50V ? It may be contradictory, but that is the MAXIMUM value. in the book. Funny but a few days ago you were entering incorrect data and then also reducing that by 20% because...
  13. E

    Max Zs entry on EIC for an RCD circuit

    In my opinion when completing an EIC, and I have to fill in a value that asks me to enter data from current BS7671 wiring regs, I generally tend to enter the data as published. i.e. if table 41.5 dictates that the maximum value os Zs in this instance is 1667, then I feel inclined to enter the...
  14. E

    Max Zs entry on EIC for an RCD circuit

    Garymo: I think 1667 took less space than 1666.66666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666666....etc :D podooser: Yes, sounds correct to me. other than the measured Zs needs...
  15. E

    Max Zs entry on EIC for an RCD circuit

    erm, try table 41.5 !
  16. E

    Advice on CU change where switch drops are unearthed

    Chri5, if you are to make such personal comments then have the decency to respond to my reply or apoligise if you have subsequently discovered you were wrong ! :lol: ] always suggesting what ?? when have I suggested anyone shouldn't be in the industry, ever ????? I gave helpful...
  17. E

    Max Zs entry on EIC for an RCD circuit

    :? On what basis/evidence/fact can you possibly disagree having read the appropriate regulations ?
  18. E

    Max Zs entry on EIC for an RCD circuit

    In the ECA quote, it does mention testing for continuity. Typically when testing for continuity in say an R1+R2 fashion, 1667 Ohm may be deemed too high or raise alarm bells ! Thing is that the above ECA artical is not to be read as being the Regs. The regs, as I have demonstrated are quite...
  19. E

    Reply From C & G Re Confusing Question.

    Cant help but fell short changed from this post. Full of promise and intrigue...Stop teasing, what was the question ???
  20. E

    Max Zs entry on EIC for an RCD circuit

    Surely not my interpretaion, just fact. (backed by the NICEIC) The thing is, one section of the regs is referring to data in a table in another section of the regs. I assume its to prevent duplication. If you divorce yourself from the issue of where the table is, thens its not really that...