Search results

  1. ericmark

    Prepping for Solar - Installing Cable

    Rules keep changing, so a conduit OK, actually cables, not so cut and dried.
  2. ericmark

    Battery size for angle grinder IAN 485600_2501 Parkside (Lidi)

    Yes, it seems they will, I see no problem with the 2 Ah for drills and garden tool, the latter is 40 volts, it uses two batteries, but the grinder one can give it some heavier work as to the drills.
  3. ericmark

    Battery size for angle grinder IAN 485600_2501 Parkside (Lidi)

    PAP 20 B1, = 2 Ah PAP 20 B3, = 4 Ah Smart PAPS 204 A1, = 4 Ah Smart PAPS 208 A1, = 8 Ah Smart PAPS 2012 A1 = 12 Ah This is the 5 batteries listed as can be used with the grinder, the first 2 are not smart at larger, the last 3 are smart and smaller for same capacity. As far as I can see there...
  4. ericmark

    Electric boiler?

    Many years ago, I visited the the alternative technology centre in Machynlleth well more towards Corris, but that is unimportant, they had built a home out of hay bales, or similar, and it retained most of the heat, it looked impressive, if one is satisfied with very small windows, and walls 2...
  5. ericmark

    RCD tripping on a light circuit

    Not really, there could be a neutral - earth fault, so may be a problem not involving the switch, but unlikely. I have already shown the tools used by the electrician, not worth buying yourself, so I would say time to call an electrician.
  6. ericmark

    Gravity fed low hot water pressure - pump?

    Parent's house, the cold water tank, was just above the cylinder, and up-stairs pressure was low, I did add a pump for the shower down-stairs, and found not really required, but remember the worry was could the pump cause air to be drawn into the cylinder, I was instructed how to plumb it in at...
  7. ericmark

    RCD tripping on a light circuit

    They can attack anywhere, but other than them, most likely is spider, slug etc. Have you opened the switch to have a look?
  8. ericmark

    Battery size for angle grinder IAN 485600_2501 Parkside (Lidi)

    The 4 Ah version seems nearly the same size and weight as the 2 Ah version. As to why it needs connecting to the phone so I can see when charged, not sure? Even tells me the battery temperature, and charge current. But why? When the third light stops flashing, I know it is charged, and when the...
  9. ericmark

    Frustration, disappointment, money blown off the scale

    375 amps, in the main we need 20 volts, plus 1 volt per 25 amps, so around 35 volts output, = 13+ KW so at 400 volts 32 amps miniums, and at 230 volts 60 amps, so clearly not something one could ever use at home. And I have not considered in rush and losses. What the second part is I don't...
  10. ericmark

    Battery size for angle grinder IAN 485600_2501 Parkside (Lidi)

    Agreed, point was however as an electrician, can't rely on having grid power, so battery pack, or generator, or direct battery powered tools. Sometimes we can isolate just part of the installation, but in the main, battery tools first, then the second drill/grinder etc, can be mains powered...
  11. ericmark

    Isolating electrics at switch/spur

    Neutral to earth either zero, or very low voltage, if zero then ohms test if neutral switched off then infinity, if not then zero ohms, and if a voltage neutral to earth clearly neutral not switched, so don't test ohms as can damage the tester.
  12. ericmark

    Battery size for angle grinder IAN 485600_2501 Parkside (Lidi)

    Well lashed out, got 4 Ah battery from Lidi £25, will likely mean other drills also work better, as an electrician, often working with the power off, it is such a pain to work with generators and large battery packs, the cordless tools are really a must, such an improvement on these having...
  13. ericmark

    Motorised Valve Problem

    I would latch the valve bleed lever, and see if it works, if so then wait until summer to change it.
  14. ericmark

    Fuse box and Washer in same room

    I hope it is OK as my sink directly below the CU. Only showers or baths have special rules, as you're likely to be using them naked.
  15. ericmark

    RCD tripping on a light circuit

    A RCBO supplies one circuit, when it trips we are 95% sure it is that circuit, note the yellow test button, it may be twin or single pole, but since it is unlikely be protected by an upstream RCD it does not matter. The MCB is normally single pole, so even when switched off, there can be a...
  16. ericmark

    Isolating electrics at switch/spur

    FCU one hopes will have a double pole switch, but the line can be locked off by putting a lock through the fuse carrier. Lights switches not so easy, my light switches I would never trust, I could remove the batteries, but I would always switch off at the RCBO, and to be frank, not sure if they...
  17. ericmark

    Electric boiler?

    Had the heating worked reasonably when we moved in, then likely I would have done nothing. However, it was a complete mess, and my attempts to correct it, were not as required to start with, so I looked at why, what had I done wrong. As I am sure with most who try to improve the heating, I...
  18. ericmark

    Electric boiler?

    Down to age, I was in a house with gas hot air central heating, and floor to ceiling picture windows in the 1978 winter of discontent and after that I vowed never again would I rely on electric for heating. My dad, from Lancashire (although now called Cheshire) would say "You know what...
  19. ericmark

    Electric boiler?

    My oil boiler will continue to run, until my batteries go flat, and the solar could mean they could last for weeks. I also have one open fire, which I do not really want to use. The last house had a gas fire and flue bricks, so again a method to heat house with no mains electric. As long as...
  20. ericmark

    New RCD needed - probable cost.

    Should give you an idea what they look like and cost, I went for around the cheapest I could find. Again the whole unit, with surge protection and isolator. In the main, an electrician wants to charge by the ½ day, it takes time to move from job to job, and with a consumer unit charge to worry...
Back
Top