Search results

  1. ericmark

    Can I install a consumer unit above a radiator? UK

    Be careful with British Gas, I had solar panels fitted, BG told me they will not accept the reading from the meter fitted by the solar panel installers, which was fair enough, I would need a smart meter fitting, again no problem, then when I completed the forms to get paid for export, they said...
  2. ericmark

    Hive & Main Eco Compact

    The whole thread is about Hive, I will admit I don't have Hive, I have Wiser, and I will also admit my Wiser systems is not all Wiser but a mixture of many different makes, but be it Wiser, Hive, EvoHome it does not really matter, the whole idea is the TRV is king, and the hubs, programmers, or...
  3. ericmark

    Hive & Main Eco Compact

    Can you give a link to Hive TRV's without batteries?
  4. ericmark

    Help with ufh wiring

    Sorry, I would not personally install UFH as to save money, I only heat rooms when in use, and the heat-up and cool-down times with UFH are too long for it to be a system I would want to use. As far as I can tell, you need to use the heatmiser unit for all the heating, it has relays inside it...
  5. ericmark

    Hive & Main Eco Compact

    They look like batteries to me! This set of instructions shows how to change them on page 11, 17 and 18. British Gas do of course make non-electronic heads, but a Google for "non-electronic hive TRV head" gets the result Maybe you can point me to non-electronic hive TRV heads? There is a...
  6. ericmark

    Hive & Main Eco Compact

    That's my battery changed. and not easy to find battery state main page click this which goes to settings, click devices and that shows the first page with all four Wiser units I have, then the third one down showing the TRV, and it shows second picture shown. I went to insights heat report...
  7. ericmark

    Help with ufh wiring

    nothing connected to com so will not work, likely needs a link wire com to line. Also they look disconnected?
  8. ericmark

    Fixing TT earthing problems and gas bonding for an EV charger

    I had added a fault resistance, I had not worked it out, 0.030A x 15Ω = 0.45 volts before the RCD would trip, or 7.7kΩ to trip a RCD at 230 volts. The 15Ω is about what a 15 amp appliance would be. But as said the diagram did not really matter as to the ohms given, as no ohms for the body.
  9. ericmark

    Fixing TT earthing problems and gas bonding for an EV charger

    60Ω + 15Ω = 75Ω then 230 volts / 75Ω x 15Ω = 46 volts, so that is maximum volts to earth. Have I made an error?
  10. ericmark

    Fixing TT earthing problems and gas bonding for an EV charger

    230 volts bonding and the resistors are just red herrings, This less than 50 volts, well less than 46 volts, the actual value would need the resistance of the body. The right hand 15Ω can really be ignored, it is a near short circuit when compared with bodies resistance. What is more of a...
  11. ericmark

    Lighting Circuit

    The difference is permeant line at the lamp, and you can have emergency lamps and ceiling fans with ease, and neutral at the switch means you can fit smart switches which don't require a minium load or batteries. As said, you can have both.
  12. ericmark

    Dodgy Superser portable Butane heater.

    I seem to remember burning a gallon of petrol produced a gallon and a half of water, but this was when I was an apprentice back in the late 60s early 70s, and one would see while the exhaust pipe was still cold the water running out of it. The emergency gas fire with limited to 2 kW, boats...
  13. ericmark

    Dodgy Superser portable Butane heater.

    I have a flue-less heater fitted after the 1978 winter of discontent to heat the house during power cuts, when there was power, it was hot air central heating, so house very dry, so the moisture from the flue-less fire was welcome. But for normal heating, some method to remove combustion...
  14. ericmark

    Fixing TT earthing problems and gas bonding for an EV charger

    Sorry I intended to say IT. Yes need bonding with a TT.
  15. ericmark

    Fixing TT earthing problems and gas bonding for an EV charger

    So any TT installation is a C2? I do remember my father-in-law getting a contractor to rip up and re-lay the floor in an operating theatre, as the wrong glue used, and the floor's bonding was compromised. Seems it needed a glue which could conduct to stop static build up. Nearly every other...
  16. ericmark

    Huh?

    Oh, he's a good laugh, why not. As to why he publishes his errors, is anyone's guess. Not saying I am perfect, but I would not publish YouTube videos of my errors. I think it was channel 4? Where they had some builder saying how others had made errors, but he also made errors, quoting...
  17. ericmark

    Hive & Main Eco Compact

    Oh, I had that with a little thermostat, this style the low battery was not on, and the thermostat clicked, but it did not turn central heating on until I changed batteries. It seems Hive is the name of company, not the name of a single thermostat, and there is a whole range of Hive...
  18. ericmark

    Replacing Honeywell R6660D with Hive

    These are the heads I am using, the Energenie can only be set using a computer or phone no option to manually set, actually a pair more like £80, since it needs a hub, not worth it for you, the Kasa also needs a hub, but far cheaper, and if anything better, as the app shows how well it has been...
  19. ericmark

    Huh?

    The whole idea of someone making a video with blatant errors in judgement is a problem. If on this forum, I try and explain how lights don't give out light, but suck in the dark, pointing out to support this that tungsten light bulbs go black at the base when full, and they have sucked in as...
Back