  1. G

    UFH Experiences and recommends please

    Have you had heat loss calcs as it’s impossible to add more pipe in the floor once it down make sure you have enough ,with a vaulted ceiling you might have to be 100mm centres I’ve always used all pex but not sure if better or worse.
  2. G

    Novellini Glax R90

    I fitted one of these a couple of years ago I’d swerve it if asked again total pita Cheers
  3. G

    Unvented water cylinder leak

    Who fitted the cylinder not a G 3 installer d1 into tundish and expansion valve into d2 with no tundish the trades gone to the dogs.
  4. G

    Megaflo Tank question

    Dans right will defo be the safety group that style aren’t available anymore will need to do the job properly this time.
  5. G

    Heatrae Sadi Electomax Hot Water

    Hi I’m just east of Taunton
  6. G

    Heatrae Sadi Electomax Hot Water

    Hi I’m in Taunton or close to they should be wired with two separate supplies one from off peak and the other from normal supply you can use a timer on the supply connected to the off peak but must have the correct rating for the load
  7. G

    Heatrae Sadi Electomax Hot Water

    Hi there is an off peak and 24 hr connection inside it’s probably been linked to have a permanent supply get an electrician to wire in a timer for the off peak side if your on a economy 7 or ten then set the time to the correct times. Cheers Mark
  8. G

    Heatrae Sadia Supreme 185

    Are you in a hard water area if so the manifold could be scaled up but probably solenoid passing, part are available there’s a parts list inside the cover. Mark.
  9. G

    Can I isolate CH from the HW on a gravity fed hot water system?

    Not sure how to edit but supposed to say Primatic sorry.
  10. G

    Can I isolate CH from the HW on a gravity fed hot water system?

    Hi matey goggle primatial cylinders, but your gonna have to cap the pipes . Cheers mark
  11. G

    Hot water tank overflowing

    Just a thought looking at your pic,s I would check for a leak around the bottom of you expansion vessel it may be dripping on to the top of the cylinder and running into the Center around the DHW outlet Cheers Mark
  12. G

    Some rads cold - pipe layout/sizing issue?

    Hi does your system have an air separator to vent air back over the feed and expansion tank if so my guess would be that it is partly blocked, had them before where I've cut them in half totally blocked. Cheers Mark
  13. G

    Intergas Eco RF 24 help needed

    I would agree with dan we have 60 sparks and would only trust a handful to wire up a system like that. Cheers Mark
  14. G

    Boiler lockout

    Have a look in your loft for auto/man air vent sounds like an air lock in the paperwork and getting no flow air in pump bleed via big screw in pumphead. Cheers Mark
  15. G

    Asbestos on water pipe to shower???

    Rob I would believe that's just corrosion probably just a small weep for years now stopped by the corrosion nothing to worry about. Cheers Mark
  16. G

    setting up underfloor heating

    Are the flow and return to the manifold the correct way round ? Check from cold call for heat and feel the pipes. Also check mixing valve correctly fitted so circulator draws through the mixing valve. Cheers Mark
  17. G

    Under stairs shaped hot water cylinder

    Check the overheat stats little button to left of temp dial Mark Sorry I mean right
  18. G

    Cost of CH install required

    Just thought dan might need to save money on accommodation as the price was so low. Mark
  19. G

    Cost of CH install required

    Hay dan you can stay at my place when you come down to install for op Mark