  1. G

    Boiler not firing up

    That type of stat incorporates a anti legonella program and may be faulty and raising the temp above boiler stat set point. Mark
  2. G

    Weeping compression fitting on shower

    +1 on the locktite wonderful stuff
  3. G

    unvented cylinder...split location?

    Imo I don't see a problem in that set up as long as there is no valve between combination valve and cylinder seen it before . Mark
  4. G

    Shower pods - any good?

    Yeah held together with very small screws hard to seal on the joints I would do the job properly if I were you op, it will last longer and you will be more pleased with the result. Mark
  5. G

    Shower pods - any good?

    +4 horrible things Mark
  6. G

    shaky1105

    What's hard-work on about that's a thermal store or combi store still mains pressure not low pressure ?
  7. G

    Bio mass boiler installers

    Pullers right some of it is bogs but tbh I'm not fussed they pay well and it's all pipes but rather be in a plant room sometimes especially when it p*sing down lol
  8. G

    Solar Expansion Tank Leaking / Replacement

    You need to drain down to filing pump but not when the suns out had some very warm glycol in the tank at times my advice would be to get someone who has had experience in thermal systems to change and flush an fill also check the rest of the system over
  9. G

    Bio mass boiler installers

    Hpc Somerset mostly temp office etc at the moment water supplies waste water management . Mark
  10. G

    Bio mass boiler installers

    Agree with puller used to do bio mass but gas and elect repairs and service now better money imo but have the advantage to be involved with a nuclear new build contracts there bit different
  11. G

    Megaflo Solar - Limited Hot Water from Boiler

    Just connect up the solar coil in series better in fact as there is a volume of water not heated to sterilisation temp. Cheers mark
  12. G

    heating for small cottage, with no mains gas supply

    Wood pellets and wet c/h solar thermal and a thermal store works well for me, get the thatch checked, insurance isn't to bad just have a look and budget for it Mark
  13. G

    running water noise coming from the immersion heather/water tank

    :D Ok has the noise stopped now ? Let us know how you get on Mark
  14. G

    running water noise coming from the immersion heather/water tank

    Hi Henry this air bleed you let the air out of was it on top of the little white cylinder at the top ? If so you nee to get a plumber with unvented ticket to refill the pre charge on the expansion vessel as there won't be any now. Cheers Mark
  15. G

    running water noise coming from the immersion heather/water tank

    Hi a photo of the offending unit would help in giving advice if its a megaflow the air gap would need regenerating . Mark
  16. G

    Removing shower screen

    :D+1 on that
  17. G

    Vented Indirect Cylinder, Solid fuel boiler and underfloor heating

    Hi try having a look on the gledhill site we used to use a lot solar re thermal stores to combine different heat sources and out puts at different temps. Mark
  18. G

    new house with Solar Heating question

    Ive seen combi preheat before they work through a set of valves,one to limit temp in to the comb normally 25/30degrees and another one to direct to taps if over a preset temp normally 60 degrees settings on the controller limit the temps in the store and hysteresis between the panel and store...
  19. G

    Toilet spray gun

    ;)Would squashing the pipe behind the soil pipe be backflow protection enough