    Boiler kw advice

    The boiler will hardly be undersized for radiators you have 831 may be dated but hardly ready for the grave Talking from experience as have the same boiler You don’t need a new boiler but an engineer who will look at the system and give you honest opinion. For this you need a service/ repairer...
  4. D

    Compression Blanking Nuts

    Or get these https://www.screwfix.com/p/flomasta-brass-compression-blanking-disc-caps-15mm-2-pack/64472 Blank cap will fit a 15mm fitting and a 1/2” MI The bevel in 15mm fitting may cut into the sealing washer in blank cap- blanking disc locates where the olive would fit.
  5. D

    Rip off Plumber's

    Did not know was spam. Thanks
  6. D

    Vokera linea 28. Error 04, water pressure OK. Micro switch is not pressed.

    Item 17, the plunger passes through part 23 and is attached to item 16 which itself rests on the diaphragm 15 In idle state, the spring retracts the plunger. System water is exerting same pressure on both sides of diaphragm When the pump runs, differential pressure is created across the two...
  7. D

    Vokera linea 28. Error 04, water pressure OK. Micro switch is not pressed.

    Absolutely nothing to do with 04 code. This unit activates the boiler when hot tap is run.
  8. D

    Vokera linea 28. Error 04, water pressure OK. Micro switch is not pressed.

    Sure is Vokera part no 6872 Part 6867 is the bearer plate that diaphragm sits on and spindle is part no 6888
  9. D

    Two hot water cylinders - probably daft question

    Immersion heater for UV is behind the plastic cube like cover on the cylinder On the vented cylinder immersion easily seen. Both will have a coil through which heated boiler water flows to heat the cylinder, much faster than the immersion can
  10. D

    Two hot water cylinders - probably daft question

    Immersion heater is there for that very reason when the boiler plays up. Good idea to fire up the immersion heater every 3-4 months or so to ensure it is functioning. Often see these are waterlogged and split
  11. D

    32mm condensate p trap

    How are you going to register the boiler and carry out FGA readings as required by the Benchmark logbook. Excuse me if this post seems to be a diy effort.
  12. D

    Vokera linea 28. Error 04, water pressure OK. Micro switch is not pressed.

    Circuit resistance is the other way round for HW and CH
  13. D

    Vokera linea 28. Error 04, water pressure OK. Micro switch is not pressed.

    Read my earlier post re flow manifold Have come across this issue many times What one needs to appreciate is, hot water heat exchanger is inside the boiler and radiators are connected to the boiler with long runs of pipe. Then visualise water flow though a virtual short circuit as opposed to...
  14. D

    Vokera linea 28. Error 04, water pressure OK. Micro switch is not pressed.

    Really! The pump is powered by a relay. The PCB operates the relay and 240 volts applied to the pump. No correct check circuit other than the fuse. First thing that happens on the lenea to a demand, be it ch or hw, the pump runs. Does not tell the PCB anything. That spindle has to do its thing...
  15. D

    Rip off Plumber's

    The ONLY way to pick a trades person is by 1) recommendation, 2) work carried out has been correct and reliable timewise ( say a year later), 3) Internet commendation means nothing. Have learnt from experience, great Internet commendations, but builder turns out to be a vagabond and scam artist...
  16. D

    Honeywell ST9420C Issues

    Get the user manual out and read it. Programmer does not fire anything, it just gets things moving to result in boiler operation
  17. D

    Rip off Plumber's

    With that attitude, my expertise to carry out a repair is in the gutter. Post your details so I am not ripped by you since I am a sole trader. What I charge and you accept is way it works. Some will call my charge excessive, others not is the way the system works. Also what makes you think a...
  18. D

    1st steps towards peace. Thank you president Trump

    Stormy D said he was a small man, I suppose smaller hands is more appropriate then
  19. D

    Hob with integral extraction.

    We have a kitchen where traditional extraction cannot be installed due to small size of kitchen and other reasons. I am looking for a hob where the extraction can be ducted to the outside via duct that goes behind the base unit, then it would go below the kitchen floor to the outside ( from...
Back
Top