Search results

  1. P

    Condensation where flat roof meets pitched

    There is some condernsation higher up, but very localised. This is only happening between 2 or 3 pairs of rafters, so I wonder if it is a weakness in my insulation on those, and I just need to get in there and re-pack those 3 areas. The rest, and there is 18metres of connection between the...
  2. P

    Condensation where flat roof meets pitched

    I packed 200mm Rockwool between every rafter from the flat roof side before the ceiling was fitted. I cut it around obstacles to ensure a full fit, and looked from the loft side for any light leaking. I did try to do a good job of it - thought certainly went in. What would be a standard detail...
  3. P

    Condensation where flat roof meets pitched

    Any further thoughts appreciated? :)
  4. P

    SPLIT FACE TILING ON PLASTERBOARD

    Isn't this very dependant on whether its an exterior wall or not? An internal wall is likely studwork (Metal or timber)
  5. P

    No Firrings installed on flat roof - Who’s Responsibility

    What roofer doesn't check the falls? The lack of firrings would be a quite obvious indicator..... all they had to do was throw a level around a few times and at least alert you or the builder, and then decide who was paying for and fitting firrings. However, self managing isn't always...
  6. P

    Condensation where flat roof meets pitched

    Could you elaborate....?
  7. P

    Why still cavity walls ?

    The original house is EPS above the DPC, XPS below. The extension is PIR above DPC, XPS below. For the original house, this was really the only solution - IWI is inferior for many reasons. The systems have been in use in Europe for many years from what I have been told, and their weather is...
  8. P

    Condensation where flat roof meets pitched

    Access is fairly awkward. Would 100mm of Rockwool do the job? That would be easier, I could roll it longways, and slice into it where each rafter is, and fit around?
  9. P

    Why still cavity walls ?

    Our house was externally insulated nearly 9 years ago, and we have in total 0 problems to date. We also extended recently, and build solid 215mm block, then externally insulated it, too. Window replacements are much the same (We replaced some windows 7 years ago). We moved the windows to the...
  10. P

    2 rcbos per room

    It’s all RCBOs!
  11. P

    2 rcbos per room

    Whilst renovating our bungalow, I had plenty of circuits put in. Partly to isolate faults more easily, but also as we were renovating room by room, it meant things could be kept live in various areas, whilst others were in bits.
  12. P

    Condensation where flat roof meets pitched

    Hi all, I've noticed the past week a bit of condensation forming on the back of the layboards. The temperature has been down to about 2degrees, and very wet until today. The insulation is a bit untidy, but it is continuous, The space between the warm flat roof space and the loft is...
  13. P

    Terracotta pots over lights under loft insulation

    I covered mine with plastic pots. Was easy to make a hole for the cabling. (All LED, so limited heat) Those lights look like the back of mine - Aurora Enlite EN-FD101W
  14. P

    Large bill after meter was not working

    You think every customer should validate any readings? I never do. I may check usage now and again, but if by DD doesn't get updated, I feel I am safe to assume it is roughly correct. When our water meter started under-reading the water company came out and spoke to us, and then replaced the...
  15. P

    Home Automation System

    Lutron Caseta is only available in the US. In the UK you need Lutron RA2
  16. P

    Budget sander under £50

    I have a very similar model, and for the money it's fine and has done well so far.
  17. P

    Extension - thermalite, trusses... or not?

    Absolutely, Kingspan GreenGuard is good for this. But isn't it quite common for cavity construction to fill the cavity below a certain level, thus creating a cold bridge? We have a busy family home, and with complete external insulation and modern well fitted windows, the house is a...
  18. P

    Resin driveway

    Were they travelling folk...?
  19. P

    Extension - thermalite, trusses... or not?

    Solid blocks and insulate externally.... may as well make the blocks part of your 'heat store'.....
  20. P

    Warm Roof - Fascia Insulation?

    Not really good enough, 100mm of Rockwool won’t have the same U value as the probably 90mm PIR in the cavity. He should really fit the same spec of PIR and seal it well. Could take him a while….