Search results

  1. H

    Filling loop not working, non-return valve wrong direction?

    Just an update in case this is of use to anyone in future. I did manage to top up the CH system successfully by removing the blocked valve on the water inlet side (blue in pics before), after turning off the main of course. Then connected up a 15MM X ⅜" flexible tap connector (one from Screwfix...
  2. H

    Filling loop not working, non-return valve wrong direction?

    I've found the exact parts I've got with the blue valve being the one stuck (I also removed the plastic lever and turned the spindle manually) but of course I don't want to buy a whole kit for one parr: https://www.heatingspares247.com/product/ideal-filling-loop-pack-176671/ From the manual...
  3. H

    Filling loop not working, non-return valve wrong direction?

    I disconnected the filling loop and only got a continuous dribble of water from DHW side when valves opened. I then removed the valve itself and does appear stuck with not being able to blow air through in either direction, tried "poking it" inside with screwdriver but no change so does look...
  4. H

    Filling loop not working, non-return valve wrong direction?

    I found the same but setup is slightly different with another valve on the DHW filling loop. In any case, any combination of valve positions does nothing.
  5. H

    Filling loop not working, non-return valve wrong direction?

    I was taking a look at the Ideal Logic+ 30 combi boiler we have installed (moved in 2.5 years ago, think it's about 9 years old) and saw the pressure gauge was on 0.5 bar so after googling/looking at the manual I figured it needed topping up (no errors yet though). There is a connected filling...
Back