  1. P

    Is there any/much advantage to using 10mm2 cable for an EV charger instead of 6mm2?

    IIRC the Americans do single phase charging at 60A, but I just can't see that becoming a thing here, our electrical supplies just aren't big enough to support it. Some vehicles do 3 phase charging, but you'd need to get the supply to your house upgraded to three phase for that, probably not...
  2. P

    Sleeved earthwire... again

    The requirement in BS7671 applies to "points and acessories", the definition of accessory explicitly excludes current using equipment. So we come down to the definition of "point". IIRC a point is defined as something like "a termination of the fixed-wiring intended for connecting equipment" or...
  3. P

    Can I run 3 doubles socked from 16 am rcb

    Not really, just a matter of making things smaller/thinner. In the UK caravan parks, caravans, marinas and maybe some industrial scenarios spring to mind. And remember, din-rail mount devices are used across much of the world (basically everywhere except america), even if the UK market for...
  4. P

    Can I run 3 doubles socked from 16 am rcb

    A quick google suggests 16A standalone RCDs (not RCBOs) in din-rail format do exist.
  5. P

    Can I run 3 doubles socked from 16 am rcb

    There are at least two things to think about here. Firstly, what exactly do you mean by "RCB"? that's not a commonly used acronym! To comply with current standards, your socket circuit needs both overcurrent protection and RCD protection. * A "MCB" provides overcurrent protection. * A "RCD" or...
  6. P

    Lighting earth issues - could I just run a fused spur from the power circuit

    I can think of a few potential reasons for that. Firstly if a cable is highly loaded then Firstly, if a cable is consistently highly loaded for many years energy losses can significantly outweigh the cost of the cable. Lets say a cable carries 50A continuously for 50 years. Over it's lifetime...
  7. P

    Pull cord switch, no L1 or COM

    Only the supplier can say for sure, but I don't see anything obviously wrong with them. The thinkness of the plastic and the set-back of the metal parts from the front face both look quite reasonable to me.
  8. P

    Advise on how to proceed with extending cables for bathroom extractor fan

    Another possible option, which does come with some risk but may be worth considering is to use the existing cable as a pull line to pull through a new longer cable.
  9. P

    Controlling multiple electric heaters centrally

    Their website claims you need to own a heat pump or electric boiler to be eligable panel heaters don't seem to count :( Edit I was wrpmg, the main page only mentions electric boilers or heat pumps, but the faq says "If you have a heat pump (air or ground source), an electric boiler or electric...
  10. P

    2 way switch on stud wall (image included)

    Annoyingly toolstation seem to have decided to no-longer carry the minigrid fuse modules. They are listed as "clearance" and "out of stock for delivery", when I look at collection it only shows me one branch in my area with stock. The click4electrics site seems down right now, but my last order...
  11. P

    2 way switch on stud wall (image included)

    Click minigrid is great for this kind of thing, less fussy-looking than most other modular ranges, available with both round and square edges and very affordable. Once you account for the saved backbox, I doubt the cost of doing it with minigrid would be much different from doing it with a...
  12. P

    2 way switch on stud wall (image included)

    Personally I'd probablly either use an unswitched FCU, or use a modular fuse on the same plate as the first switch.
  13. P

    Plug tops / Plug caps?

    I don't know what americans would call what we call a "boiler". But afaict "wet" central heating systems like we use in the UK are unusual in the USA. Americans tend towards "central air" systems, where heated or cooled air is pumped around the house. The "furnace" is the component of the...
  14. P

    Lighting earth issues - could I just run a fused spur from the power circuit

    That's only true if the power factor is 1, which it pretty much is for incandescents but may not be true for other types of lighting. For LEDs I would assume a power factor of 0.5. Still it would take a *lot* of domestic-sized LED lights to reach 5A.
  15. P

    Lighting earth issues - could I just run a fused spur from the power circuit

    Something to think about when doing this is how easy/difficult it will be for the next guy to find the fuse. IMO to minimise confusion the fuse should be close to (or better-yet part of) the light switch. I wouldn't want to use a FCU in one room to supply lights in another.
  16. P

    Two-pin plug anyone (shaver style)

    running the numbers. A Europlug has pins of 4mm diameter, spaced 18.6mm between centers at the base and 17.5mm between centers at the tips. That gives, at the tip an outer width of 21.5mm and an inner width of 13.5mm. A UK shaver plug/BS372 2 pin 5A plug has 16.7mm between centers, and a pin...
  17. P

    Pulled from another thread

    Perhaps more importantly, working in radians makes calculus much easier, because it avoids annoying constants in the integration and differentiation formula.
  18. P

    Two-pin plug anyone (shaver style)

    My parents have (or had, I don't know if they still have it) an old adapter with 13A plug pins, a 5A 3 pin socket and two 2-pin sockets, presumablly to BS372. We found Europlugs did not work reliably in said adapter, they would work at first, but over time had a tendancy to either fall out, or...
  19. P

    Two-pin plug anyone (shaver style)

    Do you have a make/model for the socket?