Search results

  1. Echo the husky

    Willis Heating System

    Totally not relevant to this thread, but last year I worked in a house where the elderly customer was frequently recording TV programs in the day to watch when she got back in from the farm in the evenings on a Philips V2000 machine. I instantly recognised the design of the tapes, of which there...
  2. Echo the husky

    24v transformer to fit Hager CU

    An adaptable box is designed to be adapted, a normal domestic consumer unit probably isn't? Though I've always argued if it has a DIN rail in it you should be able to install DIN mount devices. Yes sometimes care has to be taken with spacing for airflow around contactors, but a small lightly...
  3. Echo the husky

    Willis Heating System

    Here is a thermal image I took during a recent call out. The cylinder is fairly tall so the top entry element only gets about half way down. This is on the ground floor and the cylinder almost touches the ceiling, to replace the element you have to take the carpet and floorboards up above. The...
  4. Echo the husky

    24v transformer to fit Hager CU

    The Ring doorbell PSU supplied with some Ring doorbells, or available separately from Ring, fits a single DIN module way. Though there are arguments saying products not type tested by the consumer unit manufacturer shouldn't be fitted in the consumer unit. Ring also make a matching surface...
  5. Echo the husky

    Lighting earth issues - could I just run a fused spur from the power circuit

    Your post wasn't there when I replied!
  6. Echo the husky

    Lighting earth issues - could I just run a fused spur from the power circuit

    Probably the tap on the transformer!
  7. Echo the husky

    Sleeved earthwire... again

    The flex will be a short section from a connection point to the photocell, the cpc will be available there.
  8. Echo the husky

    Sleeved earthwire... again

    I keep 3 core flex on the van that has brown black and blue cores for photocells.
  9. Echo the husky

    Economy 7 Water Tank - Timer Switch

    The heated water doesn't go up the expansion pipe (ok the level might rise a bit) the cool water comes from the cylinder not the cold water feed tank, there will be no flow from the cold tank unless a tap is opened. thermosyphon is surprisingly effective, and the water will have no problems...
  10. Echo the husky

    Economy 7 Water Tank - Timer Switch

    The heated water will rise up through the heater via thermosyphon, as it does it draws cooler water from the bottom of the cylinder, heating the cylinder from the top down.
  11. Echo the husky

    Loss of circuit

    Older MEM MCCBs are known for never being able to switch them back on again after they have been switched off. A colleague tripped a 400A(!) Dorman Smith MCCB a while back. We couldn't reset it until it was dismantled and the mechanism freed. The grease used on the moving parts had turned to...
  12. Echo the husky

    Analogue or digital ?

    No not isolated. Most people just use their mobile phones for everything and have now ditched the landline phone. I have FTTC internet. Though one of the neighbors accidentally booked full fiber to my house instead of theirs, so I've had a coil of unterminated fiber cable outside the front door...
  13. Echo the husky

    Analogue or digital ?

    I was moved to BT's 'digital voice' mid last year. No warning, I phoned up to report no phone service only to be told I had been switched over! The new service has been most unreliable, frequently can't dial out, just get error message instead of dial tone, the audio quality is really harsh and...
  14. Echo the husky

    Plug tops / Plug caps?

    I have this very old NOS MK plug and socket. Even back then they are calling it a socket and plug.
  15. Echo the husky

    socket isnt even striaght......

    It's not straight to allow the water to run off.
  16. Echo the husky

    Advisory after new shower fitted

    The photo of the cutout suggests a TN-S earthing system not TN-C-S.
  17. Echo the husky

    Low voltage to shower

    Perhaps you should have had a better sparky out... There is no reason the fault could not have been narrowed down. MCB or pump sounds like clueless guesswork to me.
  18. Echo the husky

    Both rcd,s tripping with faulty light switch

    The main danger is to someone working on the circuit the neutral has been 'borrowed' from. If someone was to isolate the socket circuit, test it dead, it would appear dead. If they then disconnected the neutral wires at some point on the circuit between the consumer unit and the light, say to...
  19. Echo the husky

    Y plan no ch

    As above. Do you have 240v on the grey wire too?
  20. Echo the husky

    What's this (shower arm fixing?) called and where can I get one? (Ed.)

    The one in jj4091s link was closer than mine...
Back