Search results

  1. D

    Installing a 14.8kw Range Cooker

    The cooker is made by Rangemaster - part of the AGA Group. The model is Elan 90 with Ceramic Hob. The brochure gives power ratings for the hob of 2 @ 1.1kw, 1 @ 1.56kw, 1 @ 1.65kw 1 @ 2.02kw. Total hob rating 7.43kw For the whole cooker it states a max electrical load @ 230V of 14.8kw...
  2. D

    Installing a 14.8kw Range Cooker

    The suppliers main fuse at the meter is 100A - Type IIB - if that helps. At the consumer unit their is a 80A RCCB but I wouldn't know if the cooker circuit goes through it. We don't have any other high consumption appliances such as showers so I think these ratings should be adequate? The...
  3. D

    Installing a 14.8kw Range Cooker

    Thank you all for your experinced help. I now know what to insist on - I think. A new run of 10mm from a 62A breaker through an isolation switch mounted correctly within 2M of the appliance. I only hope the electrician does not storm off and leave me in the lurch when I broach the subject...
  4. D

    Installing a 14.8kw Range Cooker

    The kitchen is just under 3M by 4.2M and the isolator is exactly oposite the new cooker position in the 3M direction. I believe that my electrician said the isolator was OK as it had to be within 3M? Are you 'Part P' qualified - just so I know the quality of your advice? I don't think...
  5. D

    Installing a 14.8kw Range Cooker

    I am having a new kitchen fitted and replacing the electric oven/gas hob with an all electric Range cooker with a quoted max rating of 14.8kw. This will be on the opposite side of the kitchen to the previous oven. I was surprised to learn that my electrician plans to use the existing 6mm cable...
Back