Search results

  1. N

    Bosch SHV43 Dishwasher Problem

    Thanks Rocks, the spray arm was the first thing i checked, seemed OK.... The rotating diverter gizmo beneath the two outlet ducts was very stiff though (is this normal), i cranked it round manually a few times and now it seems to be OK, but for how long... it was intermittent prior to stopping...
  2. N

    Bosch SHV43 Dishwasher Problem

    Hi Folks, Our dishwasher was found to be not washing the bottom rack properly, my wife took the initiative to see if the bottom rotor is turning.... it isn't. What is involved in rectifying this problem?. Thanks.
  3. N

    Vaillant Combi Compact heating won't shut off!

    As a final note: BEWARE BG!. checked my bank this morning, they have taken £192 from me after saying it would not be charged. After a heated phone call they said it would take 10-14 days to refund it.
  4. N

    On demand heater problem

    Looks pretty neato...if it works, has anyone thought of contacting them for detailed specs, temp rise etc??.
  5. N

    Vaillant Combi Compact heating won't shut off!

    You're quite right, 1 man hour Monday, 6 man hours Tuesday - no fix no fee :-) The final repair bill came to less than a hundred quid - now that I AM smiling about.
  6. N

    Vaillant Combi Compact heating won't shut off!

    Vaillant trained guy fixed it in 10 mins, then another 10 figuring out why the boiler was lighting with the cover off, then why the fan wasn't coming on until he blew into the boiler pressure air tube. BG had refixed the air switch with both the air tubes round the wrong way AND the wires to the...
  7. N

    On demand heater problem

    You say he wired up for 3Kw, what size twin & earth cable was fitted?, is there any scope to go up to 4.2Kw?. you may have already seen these..... http://www.tanklesswaterheater.com/products1.php
  8. N

    Vaillant Combi Compact heating won't shut off!

    Just to add, after fitting all the new bits, they then took them all back again after deciding it was beyond them!. This fault really makes no sense at all. :(
  9. N

    Vaillant Combi Compact heating won't shut off!

    :cry: BG Been here all morning, changed all PCB's except fan controller - which seems ok anyway. Everything seems to be doing what it should but no power is leaving the controller to fire her up. I've got vaillant coming out next to see if they can figure it - should bl@@dy well hope so!.
  10. N

    Drilling a wash hand basin

    I see my favourite drills might come in handy here for you as well....Go to screwfix and get yourself a couple of 5mm bosch blue multipurpose drills they'll sail through like butter - take it slow with moderate to good pressure to start it off through the glaze, once it gets through that it'll...
  11. N

    Vaillant Combi Compact heating won't shut off!

    HI Spacey, operator head v -ok, no power to ignition unit. Looks like Flame Superviser board, the BG man is bringing all the boards and an air switch (though i think he ain't gonna need that) tomorrow morning after todays inspection. It was pretty neato though watching him follow EXACTLY the...
  12. N

    Rounded off screws in boiler won't budge!? - Help!

    LOL....oh i'll never tell! sufficed to say some are defeated in minutes, others are bl@@dy hard work and take hours (days even!)...
  13. N

    Vaillant Combi Compact heating won't shut off!

    Mmmm OK. Having worked with circuit boards and control systems of other sorts for over two decades i wasn't exactly 'messing' around but thanks anyway. The controller was worthy of close inspection from the begginning given the strange symptoms - it was just bizarre that the CH was locking on...
  14. N

    Rounded off screws in boiler won't budge!? - Help!

    Tip for anyone else needing to drill hardened screws or other materials; Bosch blue fluted multi purpose drills available at screwfix, they have a sharpened tungsten carbide tip which (with a green wheel) can also be re sharpened. I use 'em all the time to drill through really hard stuff, they...
  15. N

    Vaillant Combi Compact heating won't shut off!

    I've pulled the control unit, extracted all PCB's, checked solder joints refixed, reconnected leads checked connections (and air pipes) ..... still no ignition. I think I've done all I can without venturing into areas that I shouldn't go!. I'll leave it to BG now and let y'all know how it...
  16. N

    Vaillant Combi Compact heating won't shut off!

    HI Gasguru, Yep microswitches switch in and out depending on demand, as for fiddling; well before the cam switch was resolved i have to admit to pulling the control unit disconnecting all the connectors then refixing - Initially i forgot to plug on the one which is just a link (at the rear of...
  17. N

    Vaillant Combi Compact heating won't shut off!

    HI Tony, well i pulled the hose and blew into it towards the gas valve with no effect. so i presume it's working :? edit to add.... the lockout button will not engage at all if this means anything?
  18. N

    Vaillant Combi Compact heating won't shut off!

    Yeah definate click after fan starts up. disconnected inline connector NTC lead. still nout!.... I really appreciate your assistance spacethegas.
  19. N

    Vaillant Combi Compact heating won't shut off!

    OK Spacey, tried that - still nothing. And yes this is now a different problem, the original one was a sticky DHW cam, fixed that only to find now the boiler won't fire.
Back