Search results

  1. P

    F&E Tank height above Radiator level

    Ok, Have checked the available space and there is sufficient room to raise the F&E tank at least 500mm above the highest Rad whilst allowing the vent pipe to raise 450mm above the F&E tank. From what I have read this would seem ok!? Thanks
  2. P

    F&E Tank height above Radiator level

    Open Vented system A friend of mine has a converted Oast House and wants a radiator in the gallery area which currently suffers from damp due to lack of heating / ventiliation. This is roughly level with the F&E tank in his loft area. How high above the highest radiator (ie new one in the...
  3. P

    Bonding & Skim coat advice please where salts are concer

    Thanks for the replies. The plaster has not blown at all. The woodburner is set inside our chimney breast. The walls that show the damp are facing the room (ie to the right and left of the chimney breast) with the right hand side showing a much larger damp area (backing onto my neighbours...
  4. P

    Bonding & Skim coat advice please where salts are concer

    About a year ago I replaced an original fireplace with a wood burner. The walls were damp either side of the chimney breast to about 800mm high on one side and only 150mm on the other. The wall adjoins a neighbours property. The property is 1890 built I hacked all the plaster off back to the...
  5. P

    Central Heating Pump Airlock ? DAB A55/130

    I bought a replacement circulating pump today for my old floorstanding oil combi (Boulter Camray 90/130) but not yet fitted it. The original pump has been getting an airlock after 20 mins or so of it running. I've noticed that the pump appears to be on the return pipe and is fitted with the...
  6. P

    Central Heating Pump Airlock ? DAB A55/130

    Thanks for your comments "advancedplumber", I will look into the wilo pump as a possible replacement. I'm just unsure if its a problem with the actual pump or not as when I took the housing off the impellor seemed to move very freely. When I turn the heating on the pump starts straight away...
  7. P

    Central Heating Pump Airlock ? DAB A55/130

    Problem - The pump stops operating after a while but starts again as soon as the centre screw on the pump is undone just half a turn. Does anybody know if this is more likely to be a faulty pump or would it be air getting in the system (even though all rads have been bled and operate well)...
  8. P

    Central Heating Pump Airlock ? DAB A55/130

    Hi, My central heating pump seems to have a mind of its own over the last few years when we start to use the heating in winter. I have a combi boiler and when the heating is turned on the pump whirls into action but after a while it will just stop. I recently flushed the system with Fernox and...