  1. 333rocky333

    10 mm cable joimt

    I feel the same about lever wagos, for situations with solid strands I prefer the NON lever push in wagos. For 6mm they do a Red 3 port, which is ideal for this situation and the cable seems a very tight connection.
  2. 333rocky333

    Solve an argument: Should you turn ALL of the main switches off when working on electrics.

    I find it's good practise in any situation to reduce the load using the mcbs prior to operating any main switch and reverse this process when switching back on. Not saying its always necessary to isolate the supply via the main switch, the important thing is that safe isolation and test...
  3. 333rocky333

    Rewiring Lawn Mower - Power Switch

    Though you may find the ferrules also stiffen the cable enough to allow the cable to push into the terminals
  4. 333rocky333

    Mains indicator LEDs

    Bg socket
  5. 333rocky333

    Mains indicator LEDs

    Broke one open and this is inside, looks like a neon, If you want John give us a few weeks and I may have a few more, if you want them I could post them
  6. 333rocky333

    Mains indicator LEDs

    Looking at there Tech spec on TLC seems they still use neons, will break one open soon get some pics
  7. 333rocky333

    Mains indicator LEDs

    You asked similar in 2017 and at the time mk still sold there neons, maybe now they also have an led version. It may be easier to find a brand that does use leds and remove from an accessory. We replace a lot of damaged bg sockets, they have a light on. Next time I do one I will break open...
  8. 333rocky333

    Test equipment

    Having a clear out. Have listed a kewtech KT71 PAT tester on ebay if anyones interested, going cheap, also soon to list a metrel MI 3125 multifunction tester, any interest message me. Also some older test gear, working as far as I know but no time to test it all really, including another...
  9. 333rocky333

    Correctly wired LED dimmer?

    The dimmers shown and the one you intend purchasing appear to be 60w minimum load. Your 6 spotlights are unlikely to meet that requirement unless for led loads the dimmer rating is different.
  10. 333rocky333

    Odd GU10 to GU10 adapter

    Google LONG NECK Gu10 you can get 6000k ones
  11. 333rocky333

    Do cables wear out if used too much?

    No it's in free air, its all cracked and when touched just crumbles, the outlets are on the main ceiling slab and they dangle down to the false ceiling 600mm lower. Because of the nature of the premises the temperatures a tad average than normal though nothing drastic. The cable is well marked...
  12. 333rocky333

    Do cables wear out if used too much?

    Not sure what's happened here, cables only a few years old and most of the flexes from the plugs to the lights within the ceiling Void just crumbling away
  13. 2024

    2024

  14. Screenshot_20240324_203700_Gallery.jpg

    Screenshot_20240324_203700_Gallery.jpg

  15. Screenshot_20240324_203646_Gallery.jpg

    Screenshot_20240324_203646_Gallery.jpg

  16. 333rocky333

    High Integrety CU - Internal cabling

    I have mentioned them a few times :giggle: I recently sheared my modulo head on my torque driver the maker replaced it free and give me some surprising news relating to modulo head screws in dist boards, if your interested i will try and pm it to you as i dont want to publicly announce it
  17. 333rocky333

    ring doorbell

    Yes all correct thats what i was seing and the back is the same with the same label, thanks, though i find it odd why Ring only seem to sell a Dc transformer which seems to be DC with unmarked spade ends when tested with a meter., it also suggests putting the seemingly unmarked positive...
  18. 333rocky333

    1.5" fluorescent tube fittings

    Do not really underrstand the question . Tri phosphor tubes would be T8 and a 1.5 inch tube would be T12, both of these use the SAME bipin fitment, unless your fittings are from the 1960's. where you may have needed a BC to Bipin adaptor. Whether T8 works in the T12 is down to the control...
  19. 333rocky333

    ring doorbell

    I have i believe a ring doorbell 5 i have lost the book, scanning internet it seems i need an AC transformer, however the transformer i bought is a Ring plug in job, but it appears to be DC . Bit confused what is right to do as Ring do not seem to sell an AC version. Obviously i know i could...