    Tools stolen from uninsured house- What would you do?

    Some silly comments on here. The lads van was off the road so it was difficult to get them home and back again. We can all take the moral high ground and say what he should have done from in front of a computer screen. Im sure those commenting would have done exactly the same.
  2. P

    Heatline Monza 24/28 combis-marks out of 10 please

    Fitted one last year and was called back one week later. Diverter valve motor head had failed. Turned out a "plumber" fitted a tap in the bathroom resulting in water hammer. Everytime any tap was closed the boiler fired up for a split second thinking there was a demand for dhw. It must have gone...
  3. P

    Diameter Of Waste Pipe: What Size?

    Google approved document H, sanitation. Longest run in 40mm allowed is (1"1/2) if I remember righlty is 3M. You need to make sure its on a gradient which is more pertinant than the bore of the pipe.
  4. P

    New gas line – pressure test – how long?

    On water its one and a half times the maximum working pressure. On gas its...? I dont know and can't find anything in my books...
  5. P

    Best way to advertise plumbing services?

    That was entertaining if nothing else.
  6. P

    Heatline Monza 24/28 combis-marks out of 10 please

    Very expensive replacement parts. You get what you pay for. Installed many of these and had a couple of problems. Level entry boiler
  7. P

    24i (non condensing)

    Called out to an old 24i locking out after a few minuets on CH or DHW. One red flash per second. Pump seems to be running fine as does the fan. Thermistor?
  8. P

    Banging from pipes when heating comes on

    TRVs locking down can cause this. Is there a by-pass fitted?
  9. P

    Disadvantages of a closed system boiler on 1990s house

    Not a fan of fitting boilers in lofts full stop. Last resort. Regarding the pressure increase, i've had a handful of original open vented systems leaking when converting to a sealed system. To put it in to context I would say 95% of systems cope with the difference in pressure. In my opinion...
  10. P

    Air into closed system CH?

    Could just be air in the system left in there from the original fill up. You could have missed venting it out the first time.
  11. P

    Continuous air in rads?

    Much more information needed. What type of system do you have for a start
  12. P

    Vent not existing for existing Back boiler?

    I really need to up my prices. Fitted a stadium 100cm2 vent last week, £80 supplied and fitted. There will be some form of benifit loan to pay for this. Get a gas engineer to give you a written quote and get him to put a side note on there stating the importance of this vent for the customer.
  13. P

    Heatline Vizo 24, Heating works but no hot water

    Any links? only one I can find on there is 19.99 + 2.50 p+p
  14. P

    Vaillant VCW GB 221 CH too hot and shut down

    Tell him what you have typed. That will be more than enough.
  15. P

    Ball park cost for installing Solar HW

    my average £2500-3500 :-)
  16. P

    air in system

    Could be a plumbing issue. The vent, inlet and pump should be within 150mm and be in that order. Vent Inlet Pump. Check the system has been installed with this method. Air could be getting drawn down the vent in to the system if its plumbed in wrong.