Search results

  1. W

    Worcester 28i junior

    The low pressure switch could be blocked (top rright its got 2 wires to it and its circular in shape,try taking it out and see if its dirty,if you can gently push something into it and hear it click.have you linked it out
  2. W

    Worcester 24i, hw keeps going off

    It may be the harness loose,but i suspect the pcb is about to give up,
  3. W

    No header tank. no heating, no hw and boiler packed up.

    BOOOOOOOOM,be careful if im thinking correctly then its very very Dangerous
  4. W

    No header tank. no heating, no hw and boiler packed up.

    No tank,any expansion pipe?,it sounds dangerous,no water in system,get it looked at asap.Who was the plumber? did he leave his horse in the garden?
  5. W

    servowarm elite 50 not ignighting

    What type of mzv(motorized valve),is it the old servowarm type,that's got to be moved manually or is it a 2 port honeywell valve
  6. W

    Boiler fires up but no hot water or heating

    Your header tank is the smallest tank.If its empty then try moving the ball valve arm,it can empty through having a leak,venting system or over the years its been filling system without being filled up.I would get in the loft,check your h/tank,if its full,ok,did you check the rads were full,
  7. W

    Boiler fires up but no hot water or heating

    What make is it?. Is it a potterton profile?. I mean is it fully pumped or gravity circs for h/w. Can you see a mzv(silver box)with cable to it.Have you a roomstat on the wall. See if it fires up the heat must go somewere,how hot do the pipes at the boiler get?
  8. W

    Boiler fires up but no hot water or heating

    Does it start banging or stays on for a minute then cuts off,then a few minutes later fires up again,it could be your pump,or it may be lack of water. Our the rads full,is it fully pumped or gravity circs,(2 or 4 pipes) you will have a gas pipe as well so 3 or 5
  9. W

    Any one else made to feel a fool by technical helpline's

    Gas4u,excellant point. He also blamed circulation,i explained in detail to him,what was happening.I made sure i had multimeter handy,so i could go through the correct proceedure's,as agile says "it might not have been the pcb",thats why i will ask for advice if im not certain what the fault is.
  10. W

    Any one else made to feel a fool by technical helpline's

    I am grateful for the replies boys,i feel better knowing i wasnt just upset due to my lack of knowledge. I like to learn of other engineers who are able to carry out boiler fault finding,at a higher level than myself.I am twenty four now,so i admit i am a newcomer,but i carried out c/heating...
  11. W

    Any one else made to feel a fool by technical helpline's

    Im not looking to cause anyone hassle,but thanks anyway G4U.I felt it more as i was in the customers house,and she was there when i said to him "listen mate,i work on all makes of combi,so i neeed your help,to find certain parts to check" and to be honest i always speak politley as i find,being...
  12. W

    Any one else made to feel a fool by technical helpline's

    I was made to feel a total idiot,by a ariston technical engineer. I rang and explained how the euro mffi 23 combi wasnt working,all i had was pump running,no c/h or h/w. I was pretty sure it was a pcb fault. It would go to lockout after 20 secs,no sign of anything except pump running,then...
  13. W

    apollo pilot light wont stay lit!!!

    Id say overheat stat,if youve changed t/c,but could be gas valve,are you rgi,so you could link the o/h out
  14. W

    Ariston combi proplem

    I would appreciate any advice please. I went to a ariston euro mffi combi,it's pump would run,but then nothing,no fan.Its the same on c/h & h/w,then after about one min,it goes to lockout(red light comes on).I am getting a pcb,but is there anything else im overlooking.
  15. W

    Worcestor 24i Junior erratic fan

    Is there 240v at the fan,when you say,you have to blow to get it to fire,do youu mean you have to give the fan a bit of help,for it to spin.If youve got 240v at the fan,then its the fan,
  16. W

    Worcester boiler shutdown after a few hours

    It may well be a build up of carbon in the h/ex.If it was ok when the o/h stat was linked out then it points to when it reaches temp,the boiler cant cope with the excess heat and if theres a blockage it cant push the excess heat around properley,the old 240 were well known for it.Try a chemical...
  17. W

    Removed combi for safety,now its got a few proplems

    I live in a quiet little village called Liverpool.I only charged him £70 to remove it,you know yourself,you think 30min work.Itss actually leaking from the middle of the h/ex,i am a fair lad,but i admit i did get a ****ed off and told him"stick your boiler up your a???",right or wrong.I only...
  18. W

    Removed combi for safety,now its got a few proplems

    I removed a 24i junior,while the house was empty,so it wouldnt get robbed. This was in january,i went to refit it today and as it was working before i took it out,i didnt expect any proplems.I filled it up,wired it and fired it up. And nothing happenend,then the h/ex started leaking and then the...
  19. W

    wb 28irsfcombi packed in

    Agile,what do you mean?. Im just giving advice
  20. W

    wb 28irsfcombi packed in

    Check overheat button,on top of boiler,left hand side,if its up a bit,press down and see if its ok