  1. Elkato531

    dripping valve next to hot water tank

    Its a manual vent not an automatic one. Tighten the cap a bit with a pair of pliers.
  2. Elkato531

    Bath waste clicker or turn overflow type

    Regular use is essential for clicker wastes. If you usually shower and the bath waste doesn't operate for months on end, it'll seize up. Same with basin wastes. Never have reason to fill a basin so clicker waste locks up with crud.
  3. Elkato531

    Range Tribune (Pressure at 0 & Cold radiators No heating ) Urgent help requested please

    Don't touch the unvented cylinder components. As terryplumb says, you are not qualified to do it. Also, if you tamper with it, the landlord or their agents will likely then blame you for any problems they find and will send you a bill for repairs.
  4. Elkato531

    Grips

    Are they the auto adjusting type? Possibly too clever for their own good. I've had Knippex before. Very good but expensive and I have a bad habit of losing tools. Have had these for a while and they are good enough and cheap. https://www.screwfix.com/p/magnusson-water-pump-pliers-10-254mm-/9689v
  5. Elkato531

    Range Tribune (Pressure at 0 & Cold radiators No heating ) Urgent help requested please

    If your heating doesn't work, pester your landlord until they sort it out. It is their responsibility and part of what you pay all that rent for. They should also explain how to control the system and how to do basic maintenance like topping up system pressure if relevant.
  6. Elkato531

    Is adding an indirect cylinder to a combi boiler the right solution?

    In a combi or unvented set up, all outlets share the incoming mains water so that has to be your starting point. Get it tested for pressure and flow rate because if it can't supply enough water, neither option will give you what you are after. A cold water tank, vented cylinder and pumps can...
  7. Elkato531

    Is adding an indirect cylinder to a combi boiler the right solution?

    If you want a combi and an unvented to supply hot water at the same time, the mains cold water supply needs to be up to the job. If you currently experience a drop in shower performance if a toilet is flushed or a cold tap opened, then it is likely that you could spend a lot of money for very...
  8. Elkato531

    Replace shower valve

    Wrap the pipes in felt or foam insulation and fill the void with a sand cement mix. Hopefully the 15cm is pipe centres.
  9. Elkato531

    How to turn off water to a back to wall toilet?

    If the cistern is filling really slowly and its spraying, it is likely to be a Siamp fill valve. Does it look like this one...
  10. Elkato531

    Replace shower valve

    Yes, those are the mounts. I'd use copper but plastic should be fine if used correctly and inserts are used. No wiggle room on the 150mm centres as those are the pipe centres on the bar valve. I have a piece of plywood with 2 holes drilled the correct distance apart which I use to hold the...
  11. Elkato531

    Replace shower valve

    I would fit a bar mixer using a fixing kit. https://www.screwfix.com/p/swirl-bar-valve-wall-mount-fixing-kit-chrome/8669h Remove tiles to cut out existing mixer and locate hot and cold pipes. Extend pipes and add elbows so they come straight out of the wall. Level and 150mm apart. (hot on left...
  12. Elkato531

    Compression Fitting leaking - Triton Shower Install

    PTFE on the olive, not the threads.
  13. Elkato531

    If ball valve is so great ...

    If the valve was closed and numerous safety devices failed then that is a possibility. The regulations, however, have to take the worst case scenario into account even if very unlikely.
  14. Elkato531

    Saniflo waste direct to sewer drain

    Its going to constantly spray the inside of the inspection chamber with sewage slurry so I'd say its certainly not a good idea. Almost certainly not allowed by regulations either but I don't know for sure.
  15. Elkato531

    Shower head replacement

    It looks like your shower has Mira Airboost. It is supposed to mix air with the water to give the effect of a more substantial shower flow. Not really convinced it works that well but it does mean that you need the correct Mira shower head. You may be able to remove the airboost tube from the...
  16. Elkato531

    If ball valve is so great ...

    Yes its a problem. No valves are allowed on the safety vent. If you want to add a valve to the hot distribution pipe, it must go after the Tee on the downwards section of the vertical pipe.
  17. Elkato531

    Removing this cistern flush

    The main black body needs to turn anticlockwise and the white basket base should stay still.
  18. Elkato531

    Aqualisa quartz very noisy

    Contact ourbathroom.com They recondition aqualisa processors and should be able to advise on what is compatible and supply as new quality units considerably cheaper than buying new.
  19. Elkato531

    Water meter - backwards when stopcock off

    A leak down stream of the meter would result in water passing through the meter and a forward movement of the dial. Only reason I can think of for backward movement would be thermal expansion of water in the pipe if its warmer under your floor than in the water main. This would only be a tiny...
  20. Elkato531

    Potterton Suprima - Replace or repair?

    I like the Suprima despite the PCB problems in its earlier days. However, given its age and rotted flue, I wouldn't chuck any more money at it. Too many variables to give a definite idea of price but 3k doesn't seem too far off the mark. Get alternative quotes and see how they stack up...