    John guest to 15mm arrest valve

    Never a good idea to conceal compression fittings and certainly not iso valves which have a habit of leaking. If you must have the fitting concealed, use a straight pushfit connector from plastic to copper and have the iso valve where you can get to it.
  2. Elkato531

    Potterton SUPRIMA 40L won’t turn on, trips RCD immediately :(

    Better to keep both sides open so that it doesn't create a deadleg with stationary water and the possibility of stagnation and bacterial growth.
  3. Elkato531

    Potterton SUPRIMA 40L won’t turn on, trips RCD immediately :(

    I didn't look too closely at the pipework in the pictures and didn't notice it was secondary circulation. Its job is to push hot water round a loop bringing it closer to hot outlets so that it doesn't have to come all the way from the cylinder each time a tap is opened. They are expensive as...
  4. Elkato531

    Can you work on valve-to-rad connections without draining?

    Doing it day in day out gives you the confidence to know what should work and that the trickle of water is not going to turn into a torrent. Any pro will also be able to tell you tales of when things have gone wrong. You laugh about them later but not funny at the time. I usually have a wet vac...
  5. Elkato531

    Potterton SUPRIMA 40L won’t turn on, trips RCD immediately :(

    The first thing the engineer should do is determine whether the fault lies with the boiler or with an external component. Pumps are a regular cause of tripping electrics. The fact that yours looks like it does points to it being the cause. The wiring looks like a poor diy job and certainly...
  6. Elkato531

    Can you work on valve-to-rad connections without draining?

    Compression or union? If compression, ease the joint apart and put a couple of turns of PTFE round the olive. If union, a smear of jointing compound on the tapered mating surface.
  7. Elkato531

    Can you work on valve-to-rad connections without draining?

    I regularly fit new tails to full rads. You're always going to lose some water so sheeting up and drip trays are essential. Actually, once the rad spanner is inserted on union type tails, hardly any water escapes. Have the new tail ready taped up and switch over quickly. If its a compression...
  8. Elkato531

    Toilet flush replacement query

    Have a look at toiletspares.co.uk They have pages with dozens of push buttons and flush plates. Hopefully you can match yours.
  9. Elkato531

    Is it normal for Vaillant boiler (18kwh) to have flow temperature at 48c after 1 hr of running?

    You can also reduce anti cycling time on d2. Factory setting is 20 minutes.
  10. Elkato531

    Drayton TRV 4 in bits

    The RT212 head may fit and work. Maybe someone has tried. https://www.screwfix.com/p/drayton-rt212-white-trv-sensing-head/569hg
  11. Elkato531

    How much space required to left of radiator?

    Plenty of room there if you use an angled rad valve. This will need the pipe to come out of the cupboard lower and then turn 90 degrees up the valve. If you want a straight valve with the pipe going directly into it, you may need a bit more space.
  12. Elkato531

    Yorkshire fittings advice please.

    :ROFLMAO: :ROFLMAO: :ROFLMAO:
  13. Elkato531

    Tap leaking again with new cartridge

    You can get different thicknesses of the bottom blue seal. Contact Tap Magician and explain the problem and they should be able to send you thicker seals. They are just round the corner from me and always really helpful.
  14. Elkato531

    Help! Bathroom radiator not coming on.

    On the whole, no, but there are some good people on there. I wouldn't want to tar everyone with the same brush but it is a bit too pot luckish. Best thing is to try and get recommendations from neighbours, friends etc.
  15. Elkato531

    help pls- 1 radiator not working

    Post pics of the top ends of the rad.
  16. Elkato531

    help pls- 1 radiator not working

    Anticlockwise to open yes. There will be vent points somewhere otherwise the rad could not be filled when installed. Check the ends carefully. It may be that the vent screws have been snapped by overtightening in the past. If that's the case, its new rad time.
  17. Elkato531

    Help! Bathroom radiator not coming on.

    Find another plumber who will change the valves for you. Even if the system needs a powerflush (which is unlikely if the rest of it works ok) those valves will need to be repaired/replaced first anyway.
  18. Elkato531

    help pls- 1 radiator not working

    Are you sure both valves are open? If they are, it could be an airlock. When radiators are fed by pipes dropping down from the ceiling they can sometimes be prone to airlocking. You can try turning off other rads that do work so that the pump is only pushing water to the problem rad. This should...
  19. Elkato531

    Toilet blockage - solution or new toilet required?

    Very dangerous stuff. Try all mechanical methods first. If you do use any chemicals and they don't work, be sure to warn anyone who looks at it subsequently and tell them what you have used. Also, don't mix chemicals. This can lead to reactions producing heat and poisonous gasses such as chlorine.
  20. Elkato531

    How would you deal with this cast iron bath

    Put a cover over the bath before you start. The enamel coating is a thin layer of glass and as you start smashing there will be millions of tiny razor sharp shards.