Search results

  1. G

    Vaillant EcoTEC Combi Boiler - pressure / water issue ?

    The grey taps are held on by a small screw,first make sure it's fully screwed on and also make sure the that the plastic is not broken,it might be that the taps are showing closed when they're not,hope this makes sense?
  2. G

    Vaillant EcoTEC Combi Boiler - pressure / water issue ?

    You've probably not shut the filling loop tap on the right,I'm assuming your vaillant is an ecotec plus
  3. G

    Britony Combi SE 80 DHW Problem

    Sounds like domestic hw diaphragm is worn
  4. G

    New house: cold rads & wrong thermostat settings?

    Every time you bleed a radiator you are going to have to top the pressure up using the filling loop,should be about 1.5bar when system is cold/not in use (on the red needle)the pressure will rise when the boiler is running but shouldn't go near 3bar.set your thermostat to 60deg for your hot water