  1. C

    Oh great

    2nded. pictures if you did like to see a neat CU
  2. C

    Oh great

    What IR readings did you get at the CU ? did you advise the customer it would be wise to sort out the mess within the CU ? edit grammer
  3. C

    Earthing armoured cable.

    of course he knows. but why would anyone give an incompetent person valuable advise to such who is abusive and may put lives at risk. and as for your other ranting s probably best you jog on.
  4. C

    12v MR16 lights, help problems

    a switch mode power supply does have secondary windings but are they not used primarly for Dc/Dc converters for industrial control. only ever seen transormers labelled as linear power supply. it was this one http://www.wickes.co.uk/invt/162383
  5. C

    12v MR16 lights, help problems

    :wink: just as long as your reaching the minimum wattage value, i thought they were a good price compared to screwfix allthough these wouldnt rech the minimum wattage so will get the l.e.d driver too.
  6. C

    12v MR16 lights, help problems

    just found these http://www.tlc-direct.co.uk/Main_Index/Lighting_Menu_Index/Lamps_and_Tubes_Index/MR16_Led/index.html
  7. C

    12v MR16 lights, help problems

    :?: just had a look at the transformer its rated at 35 - 105 watt, the person who put the bulbs in says they we're 40 watts equalling 240 w load oops. i'm going to install 6 x 7 watt l.e.d bulbs (42 watts). still using the 35 - 105 watt transformer without causing over voltage for the l.e.d...
  8. C

    12v MR16 lights, help problems

    Hi i have 6 robus bathroom lights that run off a 12 v transformer. The problem is that after around 10 mins they start to dim and and then hardly any light is ammited. a live swith wire comes from a jb goes to a pull switch, then the transformer input is wired to the neutral and switched live at...
  9. C

    fault finder

    yes
  10. C

    fault finder

    The rcd does not trip when the mcb is switched off.
  11. C

    fault finder

    You say the rcd tripped off but Did the actual 16 amp mcb trip at any time yes
  12. C

    fault finder

  13. C

    fault finder

    all appliances were un-plugged so i dont believe a pat tester was needed. i dont do domestic work. but the company i work for mainly repair electric motors and work in other electrical sides that are covered from various part p schemes. im off work and don't have the IR tester so this was why...
  14. C

    fault finder

    yes
  15. C

    fault finder

    Happy new year to all. yesterday my elderly next door neighbour said that her fridge freezer wasn't working. i went to have a look and found that an rcd had triped. ( 2 way consumer unit 1 rcd for 3 socket circuits ) i replaced the mcb for the down stairs sockets ciruit that was at fault...
  16. C

    flooring expansion gap around door jamb

    cant find a bosch p180e on the net any links?
  17. C

    flooring expansion gap around door jamb

    haha , yes ive got some white silicon and the beading and skirts are white so will have to do this. or try some woodulike :wink: and next time ask to undercut frames. thanks big all
  18. C

    flooring expansion gap around door jamb

    no will get one up tommorow. allthough i dont think this will be an option feel bit cheeky as hedid this cheap. unless i pay him again :? seems like i may jus have to fill with sealant or wood filler any suggestions on these? thanks
  19. C

    flooring expansion gap around door jamb

    is this still possible with the flooring allready down and most of the beading .
  20. C

    flooring expansion gap around door jamb

    it varies on the long straights its roughly 10 mm but around door jamb it varies from 5 - 12 mm