    Some CH pipes temporarily out of use (Ed.)

    1. It shouldn't cause an airlock, as it's no different from turning off all the upstairs radiators. Even if it did, you could just bleed the downstairs radiators. 2. Don't join them or you will "short circuit" the heating. Hot water will just go straight through the join and bypass the...
  2. O

    Help with Gas Cooker and Hob connection

    1. You are not allowed to make one, never mind two, gas outlets unless you are Gas Safe Registered. It is illegal to do so. 2. You will have to let a gas qualified engineer establish both outlets either: 2.1 After the cooker and hob are installed but before they are connected, even though...
  3. O

    Leaking from feeding pipe tap to Combiboiler

    Provided the stop cock below the drain off valve is working, you could easily replace it yourself: 1. Buy a new compression fitting drain off valve. Assuming the pipe is 15 mm diameter, BES Item 7802 is what you want. 2. Shut of the stop cock by screwing the handle clockwise until it won't go...
  4. O

    Hot water tank cold water inlet leak (Name of part)

    Looks like (part of) the combination valve for an unvented hot water cylinder. If so, can only be worked on by someone with a G3 qualification with current accreditation to an approved G3 scheme.
  5. O

    Wobbly bathroom mixer tap crisis.

    Normally with that type of fixing the threaded rod, which is hollow to allow for the "pop up waste" operating rod, has a hexagon on the inside. You put a long Allen key of the right size down the operating rod hole (after removing the rod!) and tighten by turning clockwise looking down.
  6. O

    Difficulty with dripping tap

    1. With the retaining screw undone, the handles will just pull off. However, time and limescale may have jammed them on. Try pouring very hot water over them and levering off with a broad bladed screwdriver, but watch the chrome-work. 2. The right hand tap (with the bigger gap) has probably had...
  7. O

    New combi boiler fitted - not flushed, no inhibitor added

    1. System can be drained via a radiator valve. More fiddly than if drain off fitted but plumbing 101. 2. Who knows. 3. The system should have inhibitor in it. If you are going to do a chemical flush it would be sensible to do that first. As mentioned above it can be done without a drain off...
  8. O

    Bizzare toilet problem

    Have you pushed the flush pipe too far into the pan so that water cannot flow in fast enough?
  9. O

    Cannot seem to tighten valve onto radiator feed

    1. Can't tell for sure from your photos but looks to me as if a fitting has been inserted into the end of the pipe, presumably soldered. 2. I've quite often found these fittings, which are designed for end feed soldering, often offer a slack fit for a compression fitting. 3. You might try...
  10. O

    New combi boiler fitted - not flushed, no inhibitor added

    1. His excuses sound like rubbish. Any system can be drained and refilled - how did the water get into it in the first place? 2. Check the installation manual for your boiler, which he should have left with you after completing and signing the checklist at the back. If Worcester insist on a...
  11. O

    Alu Radiators

    1. There is no difference in heat output of aluminium versus steel radiators of the same designated heat output. The aluminium one is likely to feel warmer more quickly, but will then go cold more quickly. 2. It is likely that the water going into the radiators with the heat pump is cooler...
  12. O

    Shower valve and cover

    1. The head of the insert is larger to accommodate the extra O ring. 2. The other O ring can prevent the olive of the compression fitting from sealing properly.
  13. O

    Shower valve and cover

    As Madrab says, you shouldn't use Superseal inserts with compression fittings. Use the plain inserts (Screwfix item 64318) instead.
  14. O

    Cylinder replacement - no boiler

    1. 2 bar dynamic pressure is at the lower limit for an unvented cylinder. Worth checking you do get this pressure, and at different times of the day. 2. You need a flow of at least 20 litres per minute (cold main, "open pipe" flow). 3. You would almost certainly need some pipework changes...
  15. O

    Detecting an underground water leak

    Could it be a previously mis-read meter?
  16. O

    Detecting an underground water leak

    1. Locate your internal stop tap, fitting a new one if necessary. 2. Turn off the water to your property using the internal stop tap. Make a note of the meter readings at the same time. 3. Leave water off for as long as possible. (Or repeat exercise). 4. Before turning the internal stop tap...
  17. O

    Small cistern & fluidmaster

    1. To turn the syphon round you have to have an alternative hole on the left hand side side of the cistern to fit the handle through. Not all cisterns have this. 2. You may also find that the cistern fouls the overflow pipe, in which case you have to change the syphon as well for one with an...
  18. O

    Replacement boiler - TRVs and 55 degrees ?

    1. For a condensing boiler to operate at high efficiency, the RETURN temperature at the boiler should not exceed 55 degrees. At or below 55 the boiler will work in condensing mode. Above 55 it won't. 2. With a condensing boiler, the temperature drop across each radiator should be about 20...
  19. O

    Drayton TRV 4 in bits

    1. Danfoss or Pegler. Seem fine but have only been using for a couple of years. 2. You can just replace the head by undoing at the knurled metal ring. But: 2.1 The heads are quite expensive. 2.2 Unless the quality improves, you may have the same problem in a few years.
  20. O

    Airing cupboard can I do this?

    1. If you mean an electric "greenhouse" type radiator, then assuming you have removed a hot water cylinder to fit the combi, then there should be enough space that the heater will not interfere with the boiler. 2. However, the cost of running such a heater is likely to exceed the cost of...