Search results

  1. B

    Boiler issue - suspect good cleaning required and advice needed

    what is the size of the pipework to your radiators?
  2. B

    Ideal boilers

    they are alot better, the vogue is very good. they have had a few issues with hex leaks but get fixed under warranty most makes and models have a period of specific problems, same with cars and many other things.
  3. B

    Condensation in Bathroom

    you may find that before your paint allowed your plaster to absorb some moisture and now its sealed over with new paint, that and the fact this winter seems alot worse then normal for condensation. well it seem it in my house.
  4. B

    I have a leak . . . . . what's this . .???

    gate valve is my first thought
  5. B

    Immersion too hot - thermostat problem?

    its fine. make sure some of the white mechanical cover of the flex is past the clamp. start stat set at approx 50-55 and increase if not hot enough
  6. B

    Pressure fault diagnosis and consequences for repair

    I agree it sounds like the engineer has caused damage unrelated to the original fault.
  7. B

    15 or 22mm connections on system boiler

    the appliance connection size should not be used as a guide to the systems required pipe size, the system should be designed as required.
  8. B

    Replacing a freestanding gas hob with an Integrated one

    probably did not word it that well but i did mean get an engineer to do the "work" not just check it after its done :) . I would hope any GSR engineer would not be stupid enough to just check/ commission somebody elses install but we know its done by some.
  9. B

    Replacing a radiator

    20 plus wrapps of ptfe is not uncommon with poorly made fittings and rad threads, also some ptfe tapes are alot thinner than others, for example the one with the blue outer cover which i think is eagle brand is awful tape and i refuse to use it.
  10. B

    Combi Boiler Pressure

    was it serviced/ checked before you got the property? do you have Indemnity insurance with the purchase? you need to be a gas safe engineer to remove the case on this boiler, best get a local engineer to take a look. Water should only leave the overflow pipe at 3 bar and above assuming the...
  11. B

    Replacing a freestanding gas hob with an Integrated one

    as above, a cooker hose can be used if allowed by the manufacturer and not behind an oven. Oven will be to hot for hose. the hose will need to hang free and not be at risk of damage due to draws etc.... all in all the best solution in most cases is solid pipework. also if no oven under neath...
  12. B

    Potterton Puma 100e

    pump was a common fault on these due to poor quality. fitted loads in the day and about 5% had to have a new pump within a week from new.
  13. B

    Free boiler for pensioners - system not flushed? no magnetic filter?

    its a good idea to give grants for boilers to thoses that need it, the bad bit is the scum of the earth companies that tend to install most of them. It should be that the grant is for the person in the correct situation and any registered engineer can claim the grant monies towards the cost of...
  14. B

    Do Kitchen Lever Bib Tap Upstands Develop Stress-problems?

    use brass nuts and top hat washers and then pipe up in copper.
  15. B

    Any ideas on how to increase the water pressure?

    the installer should not have fitted a system that would not work as designed with your proertys supply.
  16. B

    Can I hide radiator heat reflector in the wall?

    probably best to allow the plaster to breath beneath the timber cladding.
  17. B

    Bathroom renovation - which order?

    sumet like this strip out 1st fix plumbing (pipes in walls to hide from site) 1st fix electrics (cables for lights, fan, mirror, plinth lights etc..) sub flooring for type of flooring plastering/ patching tanking tiling grouting 2nd fix plumbing and electrics clean mastic up you will need all...
  18. B

    Incorrect installation by British Gas - What to do?

    ive had this very same issue with a BG installed boiler. It was at a house i was fitting a bathroom and i was asked about the boiler pressure and i got the customer to call BG back as it was under warranty scheeme. BG engineer came and found the exp vessel not connected. i also know a BG...
  19. B

    speed fit on kitchen celing over sink

    maybe i was pointing out that because somebodys english is not upto your standards does not entitle you to criticise them for it. people dont do good english for many reasons....... Lack of education, learning difficulties or whatever. No need to belittle somebody for it. my need to comment is...
  20. B

    Public Liabilty Insurance

    depends who is legally classed as the duty holder. If your working on a commerical property they should inspect and agree with your rams etc..... in domestic properties the home owners/ landlords have a duty to inform workmen about hazards like asbestos but would not be expected to check the...
Back
Top